17
TABLE 2- Correspondence Table when checking Options
No.
Inspection
Item
Option connect
status
Inspection
result
Correspondence
9
PCIE ASIC1
DSDF
unit connected.
OK
(If the DSDF
unit is
connected
properly, result is
"OK")
Step 1. Check the installation
status of the DSDF I/F board.
Step 2. Replace the DSDF IF
board.
Step 3. Replace the SYS
board.
11
NETWORK
LAN connector
connected
OK? [LINK
DOWN]
It is displayed as
below)
"OK[Connect
speed
*]"
* Connect
speed
:
10, 100,
1000Mb/s
Step 1. Check the installation
status of the LAN connector.
Step 2. Check and replace LAN
cable if necessary.
Step 3. Replace the SYS
board.
12
SATA I/F &
SMART
NG [LINK
DOWN]
NG [SPD]
----
If necessary, perform
HDD format and reinstall
the software.
13
USB Host
OK?
Number of USB
device
connections
(NG will not be displayed)
14
USB FAX
Two Fax boards
connected
OK?
[Fax1 detected]
Step 1. Check if connectors
(CN102,CN104) are connected.
Step 2. Check and replace the
connect harness if necessary.
Step 3. Replace the Fax board.
Step 4. Replace the SYS
board.
Continued on next page