TOSHIBA I 19 TOSHIBA I 19
Maximum heating capacity and power consumption
HWT-801H(R)W-E
Power (kW)
VLT (°C)
30 35 40 45 50 55 60 65
TO (°C)
-25 4.37 4.43 4.49 4.55 4.61 4.67 4.51 --
-20 5.40 5.45 5.50 5.27 5.54 5.54 5.31 --
-15 6.42 6.46 6.50 6.54 6.48 6.41 6.10 --
-10 7.60 7.49 7.47 7.45 7.23 7.00 6.67 --
-7 8.30 8.11 8.06 8.00 7.68 7.35 7.01 --
-2 9.35 9.24 9.20 9.15 8.97 8.79 7.78 --
2 10.50 10.30 10.28 10.26 9.88 9.50 8.40 --
7 12.39 11.90 11.83 11.75 10.86 9.96 9.07 5.08
10 13.02 12.57 12.46 12.36 11.56 10.76 9.96 5.09
12 13.44 13.01 12.89 12.77 12.03 11.29 10.55 5.09
15 13.69 13.22 13.04 12.87 12.11 11.36 10.60 5.08
20 14.10 13.57 13.30 13.03 12.25 11.47 10.69 5.06
Power
consumption (kW)
VLT (°C)
30 35 40 45 50 55 60 65
TO (°C)
-25 1.99 2.22 2.45 2.68 2.98 3.27 3.21 --
-20 2.14 2.41 2.68 2.83 3.15 3.36 3.41 --
-15 2.30 2.60 2.91 3.21 3.33 3.44 3.61 --
-10 2.55 2.78 3.04 3.31 3.43 3.54 3.67 --
-7 2.70 2.88 3.13 3.37 3.49 3.60 3.71 --
-2 2.48 2.71 2.99 3.26 3.46 3.65 3.61 --
2 2.57 2.77 3.08 3.38 3.47 3.56 3.53 --
7 2.41 2.62 3.01 3.39 3.43 3.47 3.51 2.19
10 2.42 2.63 3.00 3.38 3.42 3.47 3.52 2.06
12 2.42 2.63 3.00 3.37 3.42 3.47 3.52 1.98
15 2.42 2.63 3.01 3.39 3.42 3.46 3.49 1.90
20 2.42 2.62 3.02 3.42 3.43 3.44 3.45 1.76
Coefficient of perfor-
mance (COP)
VLT (°C)
30 35 40 45 50 55 60 65
TO (°C)
-25 2.20 2.00 1.83 1.70 1.55 1.43 1.40 --
-20 2.52 2.26 2.05 1.86 1.76 1.65 1.56 --
-15 2.80 2.48 2.24 2.04 1.95 1.86 1.69 --
-10 2.98 2.70 2.46 2.25 2.11 1.98 1.82 --
-7 3.07 2.82 2.58 2.37 2.20 2.04 1.89 --
-2 3.78 3.41 3.08 2.81 2.60 2.41 2.16 --
2 4.08 3.72 3.34 3.04 2.85 2.67 2.38 --
7 5.14 4.54 3.94 3.47 3.16 2.87 2.58 2.32
10 5.39 4.79 4.15 3.66 3.38 3.10 2.83 2.46
12 5.55 4.95 4.30 3.79 3.52 3.25 3.00 2.57
15 5.66 5.03 4.34 3.80 3.54 3.28 3.03 2.68
20 5.84 5.18 4.40 3.81 3.57 3.33 3.10 2.88
▪ Heating capacity and power consumption at maximum heating capacity
▪ Heating capacity and power consumption at maximum compressor speed
▪ Power consumption without water pump
▪ Heating capacity and power consumption are measured according to EN 14511
TO: Outdoor temperature (TK°C)
VLT: Supply water temperature (°C)
HWT-801H(R)W-E NOMINAL HEATING CAPACITY