7-2.
Operation Mode
and Control
Method
12) Auto operation
An Auto operation sets the water temperature TSC_F depending on the outside air temperature TO.
1) How to operate
Pressing the remote controller [
] button and then setting Auto mode "ON" starts Auto operation for heating.
During an Auto operation, setting Auto mode "OFF" returns to the usual manual set heating operation.
The remote controller displays "A" as the temperature during an Auto operation.
(When 2-temperature control is enabled, the remote controller displays "A".)
Long-pressing the [
] button in menu display activates the Auto-Curve DN change mode, enabling the set Auto-
Curve water temperature to be shifted by ±5K range (DN_27). When using the auto curve shift function please note
the maximum and minimum water temperature at 55 (65) °C and 20°C respectively.
* ( ): 801, 1101
Even if the temperature setting is changed during an Auto operation, the operation continues.
An Auto operation works with a heating operation only, not with a cooling or a hot water supply operation.
<ZONE1>
An operation starts at the set temperature of straight -line approximation for the following: water temperature A°C
with the outside temperature T0°C, B°C with T1°C, C with T2°C, D°C with T3°C, and E°C with 20°C.
<ZONE2>
Set temperature of the ZONE2 can be selected from two methods (DN_A2). One is a percentage of ZONE1, the other
is a fixed value.
DN_A2 = "0": Percentage method that is set by DN_31.
DN_A2 = "1": Fixed value method that is set by DN_A3, A4 and A5.
However, it is automatically controlled the set temperature of ZONE1 to be the ZONE2 or more.
Item Operation flow and applicable data, etc.
TSC_F
(°C)
A (40)
B (35)
C (30)
D (25)
E (20)
T0
(-20)
T2=0
20
TO
T1
(-10)
T3
(10)
±
5K adjustable (DN_27)
(°C)
Related DN
* ( ): 801, 1101
DN
Setting item Default range
2C Setting temperature A at T0 40 20 ~ 55 (65) °C
2D Setting temperature B at T1 35 20 ~ 55 (65) °C
2E Setting temperature C at T2 (= 0
°C) 30 20 ~ 55 (65) °C
2F Setting temperature D at T3 25 20 ~ 55 (65) °C
30 Setting temperature E at 20
°C 20 20 ~ 55 (65) °C
A1 Outside temperature T0 -20 -30 ~ -20°C
29 Outside temperature T1 -10 -15 ~ 0°C
2B Outside temperature T3 10 0 ~ 15°C
27
Set temperature shift with heating set to auto
0 -5 to 5K
TSC_F (°C)
A' (40)
B'
(35)
E'
(20)
T0
(-20)
20
TO (°C)
T1
(-10)
DN_A2 = 1
Fixed value method
TSC_F (°C)
A (40)
B
(35)
C
(30)
D
(25)
E
(20)
T0
(-20)
T2=0
20
TO (°C)
T1
(-10)
T3
(10)
ZONE 1
ZONE 2
80% (DN_31) of ZONE1
DN_A2 = 0
Percentage method
Auto-Curve in ZONE2 shows 80% (DN) of that of ZONE1,
the water temperature setting does not fall below 20°C.
The ZONE2 set temperature A'°C with the outside
temperature T0°C, B'°C with T1°C, E'°C with 20°C.
Related DN
* ( ): 801, 1101
DN
Setting item Default range
A2 The choice of how to set ZONE2 0 0 or 1
A3 Setting temperature A' at T0 40 20 ~ 55 (65) °C
A4 Setting temperature B' at T1 35 20 ~ 55 (65) °C
A5 Setting temperature E' at 20 °C 20 20 ~ 55 (65) °C
31 Auto-Curve ratio of ZONE2 80 0 ~ 100%