ELECTRICAL ADJUSTMENTS
D-1
1.
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
Use an isolation transformer when performing any service
on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
When you exchange IC and Transistor with a heat sink,
apply silicon grease on the contact section of the heat sink.
Before applying new silicon grease, remove all the old
silicon grease. (Old grease may cause damages to the IC
and Transistor).
BEFORE MAKING ELECTRICAL
ADJUSTMENTS
Prepare the following measurement tools for electrical
adjustments.
1. Oscilloscope
2. Digital Voltmeter
3. AC Voltmeter
4. Pattern Generator
5. Multi-Sound Signal Generator
On-Screen Display Adjustment
Set the VOLUME to minimum.
Press the VOL. DOWN button on the set and the Channel
button (9) on the remote control for more than 2 seconds
to appear the adjustment mode on the screen as shown
in Fig. 1-1.
1.
2.
Fig. 1-1
Use the Channel UP/DOWN button or Channel button (1-
0) on the remote control to select the options shown in
Fig. 1-2.
Press the MENU button on the remote control to end the
adjustments.
3.
4.
01 OSD
18
Function
Step No.
Fig. 1-2
NO.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
FUNCTION
COLNA
TNTCA
SHRPA
SBIASA
BRTCD
BRTXD
BRTND
CNTCD
CNTXD
CNTND
COLCD
COLXD
COLND
TNTCD
SHRPD
SBIASD
BRTCG
BRTXG
BRTNG
CNTCG
CNTXG
CNTNG
SBIASG
TVM
PVM
LVL
SEPAL
SEPAH
HFREQ
E/WDC
E/WAMP
E/WTILT
CORTOP
CORBTM
HCOMP
HBLKLA
HBLKRA
NO.
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
68
69
70
71
72
73
74
75
76
FUNCTION
OSD
OSDC
CUT OFF
HPOSI
HBLKL
HBLKR
VSIZE
VPOSI
VLIN
VSC
VCOMP
RCUT
GCUT
BCUT
RDRV
GDRV
BDRV
BRTC
BRTX
BRTN
CNTC
CNTX
CTN
COLC
COLX
COLN
TNTC
SHRP
SBIAS
BRTCA
BRTXA
BRTNA
CNTCA
CNTXA
CNTNA
COLCA
COLXA
2. BASIC ADJUSTMENTS
2-1: CONSTANT VOLTAGE
1.
2.
3.
4.
Place the set in AV MODE without signal.
Using the remote control, set the brightness and contrast
to normal position.
Connect the digital voltmeter to TP401.
Adjust the VR3800 until the digital voltmeter is 117 ± 0.5V.
2-3: CUT OFF
1.
2.
3.
4.
5.
6.
Adjust the unit to the following settings.
R CUT OFF=7F, G CUT OFF=7F, B CUT OFF=7F,
R DRIVE=3F, G DRIVE=07, B DRIVE=3F
Place the set with Aging Test for more than 15 minutes.
Set condition is AV MODE without signal.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select "CUT OFF".
Adjust the Screen Volume until a dim raster is obtained.
2-2: FOCUS
1.
2.
3.
Receive the monoscope pattern.
Turn the Focus Volume fully counterclockwise once.
Adjust the Focus Volume until picture is distinct.
•
•
•
•