AIR CONDITIONER (MULTI TYPE)
SERVICE MANUAL
FILE No. A10-005
This service manual provides relevant explanations about new outdoor unit (SMMS-i). Please refer to
the following service manuals for each indoor units.
Outdoor Unit
<SUPER MODULAR MULTI SYSTEM-i>
Model name:
<Heat Pump Model>
<Cooling Only Model>
4-way Air Discharge Cassette Type
(MMU-AP 2H)
A08-004
Compact 4-way Cassette (600 × 600) Type
(MMU-AP 1MH)
A06-002
1-way Air Discharge Cassette Type SH (2 series)
(MMU-AP 2SH)
A05-007
2-way Air Discharge Cassette Type (2 series)
(MMU-AP 2WH)
A10-007
Slim Duct Type
(MMD-AP 1SPH)
A05-007
Fresh Air Intake Indoor Unit Type
(MMD-AP 1HFE)
A06-016
High-wall Type (2 series)
(MMK-AP 2H)
A05-005
High-wall Type (3 series)
(MMK-AP 3H)
SVM-09059
Other indoor units SMMS (1 series) A03-009, A03-010
MMY-MAP0804HT8(Z)(ZG)-E
MMY-MAP1004HT8(Z)(ZG)-E
MMY-MAP1204HT8(Z)(ZG)-E
MMY-MAP1404HT8(Z)(ZG)-E
MMY-MAP1604HT8(Z)(ZG)-E
MMY-MAP0804HT8(Z)(ZG)-TR
MMY-MAP1004HT8(Z)(ZG)-TR
MMY-MAP1204HT8(Z)(ZG)-TR
MMY-MAP1404HT8(Z)(ZG)-TR
MMY-MAP1604HT8(Z)(ZG)-TR
MMY-MAP0804HT8(Z)(ZG)
MMY-MAP1004HT8(Z)(ZG)
MMY-MAP1204HT8(Z)(ZG)
MMY-MAP1404HT8(Z)(ZG)
MMY-MAP1604HT8(Z)(ZG)
MMY-MAP0804HT7(Z)(ZG)
MMY-MAP1004HT7(Z)(ZG)
MMY-MAP1204HT7(Z)(ZG)
MMY-MAP1404HT7(Z)(ZG)
MMY-MAP1604HT7(Z)(ZG)
MMY-MAP0804T8(Z)(ZG)-E
MMY-MAP1004T8(Z)(ZG)-E
MMY-MAP1204T8(Z)(ZG)-E
MMY-MAP1404T8(Z)(ZG)-E
MMY-MAP1604T8(Z)(ZG)-E
MMY-MAP0804T8(Z)(ZG)
MMY-MAP1004T8(Z)(ZG)
MMY-MAP1204T8(Z)(ZG)
MMY-MAP1404T8(Z)(ZG)
MMY-MAP1604T8(Z)(ZG)
MMY-MAP0804T8-SG
MMY-MAP1004T8-SG
MMY-MAP1204T8-SG
MMY-MAP1404T8-SG
MMY-MAP1604T8-SG

Table of Contents

Questions and Answers:

Toshiba MMY-MAP1004T8P-SG Specifications

General IconGeneral
BrandToshiba
ModelMMY-MAP1004T8P-SG
CategoryAir Conditioner
LanguageEnglish

Summary

Wiring Diagrams

1-1. Outdoor Unit Wiring Diagrams

Wiring diagrams for outdoor units including MMY-MAP0804, MAP1004, and MAP1204 models.

1-2. Indoor Unit Wiring Diagrams

Wiring diagrams for various indoor unit types such as cassette, duct, and wall-mounted.

Parts Rating

2-1. Outdoor Unit Parts Rating (50Hz)

Specifications and ratings for 50Hz outdoor units, detailing components like compressors and heaters.

2-5. Indoor Unit Parts Rating

Part ratings for various indoor unit types, listing components like fan motors and sensors.

14. Exploded Diagram/Parts Price List

Illustrates exploded views of outdoor units for parts identification and quantity.

Refrigerant Piping and System Diagrams

3. Refrigerant Piping Systematic Drawing

Systematic drawing illustrating the refrigerant piping for outdoor units (8, 10, 12HP).

4-1. Normal Operation Schematic (High Temp.)

Illustrates refrigerant flow during normal cooling or defrost at high ambient temperatures.

Control and Operation

5. Control Outline: Indoor Unit

Explains basic control specifications for indoor units, including operation selection and temperature control.

6-1. Indoor Controller Block Diagrams

Shows the functional connections of the indoor unit's control system with remote controllers.

6-7. Outdoor Unit Applied Controls

Details applied controls for outdoor units, including fan speed and priority operation modes.

6-5. Method to Set Indoor Unit Function DN Code

Describes how to set indoor unit functions using DN codes via a wired remote controller.

Test Operation and Troubleshooting

7-1. Test Operation Procedure

Outlines the step-by-step procedure for test operations and error handling.

7-2. Check Items before Test Operation

Lists essential checks for electrical wiring and system connections prior to test operations.

7-5. Troubleshooting in Test Operation

Guides on diagnosing issues identified during test operations using check codes.

8-2. Troubleshooting Method

Explains fault analysis based on check codes from remote controllers and outdoor units.

8-5. Diagnosis Procedure for Check Codes

Provides flowcharts for diagnosing specific check codes displayed by the system.

System Operation and Maintenance Procedures

9. Backup Operation (Emergency Operation)

Explains backup modes for compressor and outdoor unit failures to ensure system operation.

10. Outdoor Unit Refrigerant Recovery Method

Details procedures for recovering refrigerant from failed outdoor units.

11-1. Compressor Replacement Procedure

Provides an outline for compressor replacement, including oil adjustment.

13. P.C. Board Exchange Procedures

Details procedures for replacing indoor and outdoor P.C. boards.

Sensor Characteristics

8-9. Sensor Characteristics

Presents temperature and pressure sensor characteristics, including resistance values and output voltages.