EasyManua.ls Logo

Toshiba RAS-07TKVG-EE - Power Supply Input at Indoor Unit Terminal Block (Recommend); Power Supply Input at Outdoor Unit Terminal Block (Optional); Power Supply Input Wiring Diagram

Toshiba RAS-07TKVG-EE
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supply input Wiring Diagram
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected f rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
CAUTION
PowersupplyinputatIndoorunitTerminalBlock(Recommend)
Power supply
input
L
N
GND
L N 1 2 3
Indoor
Terminal
Block
Outdoor
Terminal
Block
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
CHASSIS
EARTH
1 2 3
PowersupplyinputatOutdoorunitTerminalBlock(Optional)
Power supply
input
GND
L
N
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
Indoor
Terminal
Block
Outdoor
Terminal
Block
CHASSIS
EARTH
L N 1 2 3
1 2 3 L N
FILE NO. SVM-19040