− 10 −
4-4. Outdoor Unit (RAS-10GA-ES2, RAS-10GA-AS2)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 − 240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance (Ω) C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
2 Fan motor (for outdoor) Winding resistance (Ω) Red-Black White-Black
(at 20°C)
235.2 260.1
3
Running capacitor
DS451155NPQB
AC 450V~,1.5 µF
(for fan motor)
4
Running capacitor
RS44B256U0213S
µF
(for compressor)
4-3. Indoor Unit (RAS-10GKP-ES2, RAS-10GKP-AS2)
SKF-240-20B
FILE NO. SVM-06039
AC 440V~,25
5
Overload relay
LPAP960B
U/T: 6.1A(80°C), Open: 135±5°C, Clse: 75±11°C
No. Parts name Type Specifications
1 Fan motor (for indoor)
2 Thermo sensor (TA-sensor) 10kΩ at 25°C
3
4 Microcontroller unit (IC30)
5 Heat exchanger sensor
10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01)
D3SBA60 4A, 600V
8 Capacitor (C63)
EKMH401VSN470MP20S
2200µF, 25V
9 Fuse (F01) BET6.3A
6.3A, 250VAC
10
V
aristor (R21, R22) TND15G-561KB0SLAA0 560V
11
Louver motor
MP24T
12VDC
12
Relay (Comp., RY01) G4A-1A-E
Rating 25A/AC250V, 3~48VDC
Micro power module (M01)
MMF-240-20-4B
AC Motor with 135°C thermo fuse
RM1260V
TMP87CM40AFG-6G61
µ