7. OPERATION DESCRIPTION
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcontroller, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [SWING] button is pressed again,
it stops swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
+
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which driving the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
LOW
+
=
MED
+
=
LOW+MED
2
MED+HIGH
2
15
The air conditioner is controlled by the controller
mounted in the indoor unit. The controller operates all
components based on the commands transmitted from
the remote control and the feedback data of the sensor
is as follow:
The temperature measurement at the air inlet of
the indoor heat exchanger by the indoor
temperature sensor
The temperature measurement at the indoor
heat exchanger by the indoor heat exchanger
temperature sensor
Indoor fan motor operation control
Louver motor control
LED display control
Outdoor fan motor operation control
Compressor operation control
Receiving the information of the operation
status and judging the information or the
indication of errors
FILE NO. SVM-06039
4-WAYS-VALVE operation control
(Heat pump model only)
Table 7-1-1
Cooling UH H M L L- UL SL
OPERATION
Fan only
H M L L-
Dry
M L L- UL SL
MODE
Heat UH H M L L- UL SL
RAS-10GK Series
rpm
1350 1300 1180 1140
1000
980
900 800 700
Air flow volume (m
3
/h) 560 540 500 460 400 390 350 300
250
RAS-10GKH Series
1350 1300 1180 1140
1000
980 900 800 700
Air flow volume (m
3
/h)
560 540 500 460 400 390 350 300 250
Model
750
270
550
180
750
270
550
180
rpm
FAN TAP

Table of Contents

Related product manuals