EasyManua.ls Logo

Toshiba RAS-10N3KV-HK1 - How to Connect Remote Controller for Wire Operation

Toshiba RAS-10N3KV-HK1
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
NOTE
Use stranded wire only.
Wire type : More than H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
1. Open the air inlet grille upward.
2. Securely remove two screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
gure 1.
4. After removing the front panel, remove the Display unit and open the
cover as shown on gure 2 and 3.
5. Arrange the control wire as detail and speci cation as shown on gure
4.
6. Securely connect the control wire to terminal of Display unit board as
shown on gure 5 (tighten rmly but not over 0.12 N·m (0.01 kgf·m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of gure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on gure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
Indoor unit
Control wire
Remote controller
How to Connect Remote Controller
for Wire Operation
For indoor unit
Air inlet grille
Front panel
Display board
1
23
Display unit
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on gure 7.
4. Insert control wire from rear side of remote controller as shown on
gure 8.
5. Fix control wire which arrange as shown on gure 9 and ! to terminal
by provided screws (tighten rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on gure ".
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on gure #.
8. Mark and arrange hole for x below screw (Ø3.1×25L) as shown on
gure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to x battery cover together with wall as
shown on gure $ (tighten rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
For remote controller
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
70 mm
5 mm
4
65
Terminal
Control wire
Notch for wire out
Control wire
Tighten rmly but
not over 0.12 N.m
(0.01 kgf.m)
78
Polyester sheet
close hole for
insert control wire
Control wire
Control wire
Hole for hang
remote controller
Remote controller
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for x battery cover
Remote controller
9
"
!
#
Control wire
Terminal
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
30 mm
10 mm
Tighten rmly but
not over 0.25 N.m
(0.03 kgf.m)
3
Stripping length of the connecting cable
Screw
Terminal
cover
Cord
clamp
Terminal block
Earth line
Screw
100 mm
10 mm
10 mm
90 mm
Connecting cable
about 20 cm
01_1115551148-EN.indd 401_1115551148-EN.indd 4 10/1/2558 BE 3:10 PM10/1/2558 BE 3:10 PM

Related product manuals