REMOTE CONTROL
4
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Sleep timer button (SLEEP)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button (PRESET)
% One Touch button (ONE-TOUCH)
& High power button (Hi-POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button (COMFORT SLEEP)
+ Filter reset button (FILTER)
, Clock reset button (CLOCK)
- Check button (CHK)
ONE-TOUCH
5
Press the “ONE-TOUCH” button for fully automated operation that is
customised to the typical consumer preferences in your region of the world.
The customised settings control temperature air flow strength, air flow
direction and other settings to provide you alternate contact with “ONE-
TOUCH” of the button. If you prefer other settings you can select from the
many other operating functions of your Toshiba unit.
Press
ONE-TOUCH
: Start the operation.
AUTOMATIC OPERATION
6
To automatically select cooling, or fan only operation
1. Press
MODE
: Select A.
2. Press
TEMP
: Set the desired temperature.
COOLING / FAN ONLY OPERATION
7
1. Press
MODE
: Select Cool , or Fan only .
2. Press
TEMP
: Set the desired temperature.
Cooling: Min. 17
o
C, Fan Only: No temperature indication
3. Press
FAN
: Select AUTO, LOW , LOW+ , MED ,
MED+
, or HIGH .
DRY OPERATION
8
For dehumidification, a moderate cooling performance is controlled
automatically.
1. Press
MODE
: Select Dry .
2. Press
TEMP
: Set the desired temperature.
Hi-POWER OPERATION
9
To automatically control room temperature and airflow for faster cooling
operation (except in DRY and FAN ONLY mode)
Press
Hi-POWER
: Start and stop the operation.
ECO OPERATION
10
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
Press
ECO
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1
degree/hour for 2 hours (maximum 2 degrees increase).
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHK
CLOCK
OFF
CLR
SLEEP
SET
FIX Hi-POWER ECO
COMFORT
SLEEP
MODE
TEMP
FAN
5
4
3
~
(
&
9
,
"
#
$
%
)
-
8
7
6
+
1
2
!
1
Press
FIX
: Move the louver in
the desired vertical direction.
2
Press
: Swing the air
automatically and press again to stop.
3
For horizontal direction, adjust
manually.
DANGER
Do not install, repair, open or remove the cover. It may
expose you to dangerous voltages. Ask the dealer or the
specialist to do this.
Turning off the power supply will not prevent potential electric
shock.
The appliance shall be installed in accordance with national
wiring regulation.
Means for disconnection from the supply having a
contact separation of at least 3 mm in all poles must be
incorporated in the fixed wiring.
WARNING
Do not expose your body directly to cool air for a long time.
Do not insert your finger or any article into the air inlet/outlet.
When an abnormality (burning smell, etc.) occurs, stop the
air conditioner and disconnect the power supply or turn off
the breaker.
CAUTION
Do not wash the unit with water. It may cause an electric
shock.
Do not use this air conditioner for other purposes such as
preserving food, breeding animal, etc.
Do not step or put anything on the indoor/outdoor unit. It
may cause an injury or damage the unit.
Do not touch aluminium fin because it may cause an injury.
Before cleaning the unit, turn off the main switch or the
circuit breaker.
When the unit won’t be used for a long time, turn off the
main switch or the circuit breaker.
It is recommended that maintenance be performed by
a specialist when the unit has been operated for a long
time.
PRECAUTIONS FOR SAFETY
INDOOR UNIT DISPLAY
1 Hi POWER (Green)
2 FILTER (Orange)
3 FAN-ONLY (Orange)
4 TIMER (Yellow)
5 OPERATION (Green)
6 RESET button
1
Hi POWER FILTER FAN-ONLY TIMER OPERATION
RESET
1 2 3
4 5
6
PREPARATION BEFORE USE
2
Preparing Filters
1. Open the air inlet grille and remove the air filters.
2. Attach the filters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push CLOCK
by tip of the pencil.
2. Press
ON
or
OFF
: adjust the time.
3. Press
SET
: Set the time.
Remote Control Reset
1. Remove the battery.
2. Press
.
3. Insert the battery.
AIRFLOW DIRECTION
3
Note:
Do not move the louver manually by others.
The louver may automation positioning by come operation mode.
A
C
L
CLEANING
RESET TIMER OPERATION
3 2 1
1 OPERATION (Green)
2 TIMER/CLEANING (Yellow)
3 RESET button
Models: RAS-13SKP Series
Models: RAS-10SKP Series
1110250150.indd 2 1/15/09 4:01:56 PM