Do you have a question about the Toshiba RAS-167SKV-E and is the answer not in the manual?
Type | Split System |
---|---|
Heating Capacity | 5.6 kW |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Energy Efficiency Ratio (Cooling) | 3.21 |
Energy Efficiency Ratio (Heating) | 3.61 |
Indoor Unit Weight | 9 kg |
Noise Level (Outdoor) | 50 dB(A) |
Essential safety rules for public use, installation, and servicing.
Warnings about high voltage, electrical shock, and refrigerant handling risks.
Critical safety measures for R410A refrigerant during installation and servicing.
Procedures and material requirements for installing refrigerant piping.
List of specialized tools needed for R410A refrigerant handling and installation.
Step-by-step instructions for recharging refrigerant into the air conditioning system.
Guidelines on brazing materials, flux, and methods for pipe connections.
Explanation of the capacity-variable control system and unit roles.
Protective control based on indoor heat exchanger temperature to prevent freezing.
Procedure for defrosting the outdoor heat exchanger during heating operation.
Visual guides for the correct placement and mounting of indoor and outdoor units.
Guidelines for safely and accurately adding refrigerant, including necessary tools.
Torque specifications for flare connections and steps for system evacuation.
Procedures for gas leak testing, system test operation, and remote controller setup.
Overview of diagnostic methods and essential safety precautions for troubleshooting.
Safety measures and techniques for inspecting electrical components in the outdoor unit controller.
Interpreting indoor unit LED flashes to identify specific fault conditions.
How to use the remote controller service mode to diagnose faults via check codes.
Diagnostic steps for when the indoor unit fails to power on.
Flowchart for diagnosing and resolving issues with the remote controller.
Diagnosing faults related to inter-unit wiring and serial communication.
Flowchart for diagnosing problems within the outdoor unit's inverter assembly.
Guidelines for inspecting the indoor unit's main printed circuit board for faults.
Step-by-step guide for replacing the front panel of the indoor unit.
Procedures for removing and installing the electric parts box assembly.
Procedures for replacing the microcomputer and associated P.C. board.
Steps for safely replacing the inverter assembly, including capacitor discharge.
Procedures for replacing the control board assembly and its connectors.
Procedures for removing and installing the compressor and reactor.