10-3. Indoor Unit
10-3-1. Installation Place
A place which provides the spaces around the
indoor unit as shown in the diagram.
A place where there are no obstacle near the air
inlet and outlet.
A place which allows easy installation of the piping
to the outdoor unit.
A place which allows the front panel to be opened.
The indoor unit shall be installed as top of the
indoor unit comes to at least 2 m height.
Also, it must be avoided to put anything on the top
of the indoor unit.
CAUTION
Direct sunlight on the indoor unit wireless
receiver should be avoided.
The microprocessor in the indoor unit should
not be too close to RF sources.
(For details, see the owner's manual.)
<Remote control>
A place where there are no obstacles such as curtain
that may block the signal from the indoor unit .
Do not install the remote control in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
Keep the remote control at least 1 m apart from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances or
noise interference.)
The location of the remote control should be
determined as shown below.
Fig. 10-3-1
10-3-2. Cutting a Hole and Mounting
Installation Plate
<Cutting a hole>
When installing the refrigerant pipes from the rear.
NOTE :
When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
<Mounting the installation plate>
Indoor unit
(Top view)
(Side view)
Remote
controller
Remote controller
Indoor unit
Reception
range
Reception
range
Fig. 10-3-3
Pipe hole
62
85
82.5
170
Indoor unit
Thread
Hook
Weight
Pipe hole
Mounting screw
Hook
Hook
Installation
plate
Anchor bolt holes
2 m or more from floor
7
1
65 mm
100 mm
Pipe
hole
Fig. 10-3-2
FILE NO. SVM-13001
1. After determining the pipe hole position on the
mounting plate (A), drill the pipe hole (65 mm) at
a slight downward slant to the outdoor side.