Do you have a question about the Toshiba RAS-18GA-ES2 and is the answer not in the manual?
Diagrams showing the physical structure and installation points of the indoor unit.
Diagrams illustrating the physical structure and installation details of the 24 Class outdoor unit.
Diagrams showing the physical structure and installation details of the 18 Class outdoor unit.
Wiring diagram for the RAS-18GFHP-ES2 and RAS-18GAH-ES2 models.
Wiring diagram for the RAS-24GFHP-ES2 and RAS-24GAH-ES2 models.
Wiring diagram for the RAS-18GFP-ES2 and RAS-18GA-ES2 models.
Wiring diagram for the RAS-24GFP-ES2 and RAS-24GA-ES2 models.
Detailed specifications for electrical parts within the specified indoor units.
Specifications for electrical components used in the RAS-24GAH-ES2 outdoor unit.
Specifications for electrical parts used in the RAS-18GAH-ES2 outdoor unit.
Specifications for electrical components within the specified indoor units.
Specifications of electrical parts for the RAS-24GA-ES2 outdoor unit.
Specifications of electrical components used in the RAS-18GA-ES2 outdoor unit.
Refrigeration cycle diagram for specified models, including operating parameters.
Refrigeration cycle diagram for specified models, detailing refrigerant flow and conditions.
Refrigeration cycle diagram for specified models, showing refrigerant path and parameters.
Refrigeration cycle diagram for specified models, illustrating refrigerant operation.
Control block diagram for specified indoor unit models, showing MCU functions.
Control block diagram for specified indoor units, detailing MCU operations and outputs.
General overview of the air conditioner's control system, roles of indoor/outdoor units.
Details on how the vertical airflow louver is controlled, including position and swing.
Explanation of indoor fan speed control, including manual and auto modes.
Describes the sequence of operations for various modes and component activations.
How the fan operates in 'Fan Only' mode, detailing speed settings.
Describes the operation sequence for cooling mode, including compressor and fan control.
Explains the operation sequence for dry mode, focusing on compressor and fan control.
Details the operation sequence for heating mode, including defrost and fan control.
Describes how the unit automatically selects operation mode based on temperature.
Explains the function and operation of the Hi POWER mode for enhanced performance.
Control mechanism to prevent overheating by monitoring indoor heat exchanger temperature.
Control to prevent indoor heat exchanger freezing by monitoring its temperature.
Describes the defrost cycle process for heat pump models during heating operation.
Conditions that initiate the defrost cycle based on temperature and time.
Criteria that determine when the defrost cycle is completed.
Functionality that restarts the unit with previous settings after power interruption.
Step-by-step guide on enabling the auto restart feature.
Information about the filter check indicator and how to reset it.
Describes the self-cleaning feature designed to reduce humidity and prevent mold.
Explains the quiet mode, which reduces indoor fan noise and speed.
Details the comfort sleep mode for quiet operation and automatic temperature adjustment.
Describes comfort sleep mode operation during cooling cycles.
Explains comfort sleep mode operation during heating cycles.
Critical safety warnings and precautions to be followed during installation.
Visual guides illustrating the placement and connection of indoor and outdoor units.
Lists and describes optional parts required for specific installation scenarios.
Lists and describes standard accessories and installation components included with the unit.
Details specialized tools required for R-410A refrigerant systems and installation.
Procedures and considerations for installing the indoor unit.
Steps to prepare the indoor unit, including removing the air inlet grille.
Procedures for installing the air inlet grille after the main unit is mounted.
Specific instructions for installing the indoor unit in an under-ceiling configuration.
Instructions for installing the indoor unit in a console configuration.
Steps for connecting the electrical wiring between the indoor unit and the outdoor unit.
Instructions for installing the pipe shield to insulate flare nut connections.
Guidelines for proper installation and testing of the drain hose system.
Procedures and considerations for installing the outdoor unit.
Detailed steps for connecting the refrigerant piping, including flaring and tightening.
Procedure for evacuating air from the refrigerant system using a vacuum pump.
Instructions for connecting the power supply and control cables to the outdoor unit.
Guide on setting the remote control selector switch for multi-unit systems.
Instructions for installing and using the optional drain pump kit for upward drainage.
Procedure for checking for refrigerant gas leaks after installation.
Steps to perform a test run of the air conditioner after installation.
Information on the auto restart feature and how to set it.
General steps to follow when troubleshooting the air conditioner.
Initial checks to perform before diagnosing specific problems.
Checking if the power supply voltage is within the specified operating range.
Troubleshooting steps for issues caused by improper wiring connections.
Explains how the microcomputer controls the unit and how to check for operational problems.
Initial assessment of symptoms to determine the likely cause of malfunction.
Explains the functions of the indoor unit controller in receiving and executing commands.
How the indoor unit self-diagnoses and indicates faults via display lamps.
Using the remote control to access and interpret error codes for self-diagnosis.
Guide on how to enter and navigate the remote control's service mode for diagnostics.
Flowcharts for diagnosing specific faulty components based on symptoms.
Specific troubleshooting steps for issues related to the indoor unit.
Troubleshooting guide for when only the indoor fan motor fails to operate.
Diagnostic steps for troubleshooting compressor failure to start or operate.
Guide for diagnosing issues related to wiring and signal communication.
Diagnosing why the outdoor unit stops intermittently after startup.
Procedures for checking and troubleshooting the printed circuit boards.
Instructions for adjusting the restart delay timer settings on the remote control.
Guide to diagnose and resolve issues with the remote control's functionality.
Procedures for replacing various internal components of the indoor unit.
Procedures for replacing parts in the specified outdoor unit models.
Procedures for replacing parts in the specified outdoor unit models.
Exploded view and parts list for the indoor unit's electronic components assembly.
Exploded view and parts list for the indoor unit's general components.
Exploded view and parts list for the RAS-24GAH-ES2 outdoor unit.
Exploded view and parts list for the RAS-18GAH-ES2 outdoor unit.
Exploded view and parts list for the RAS-24GA-ES2 outdoor unit.
Exploded view and parts list for the RAS-18GA-ES2 outdoor unit.
| Brand | Toshiba |
|---|---|
| Model | RAS-18GA-ES2 |
| Category | Air Conditioner |
| Language | English |











