49
Fig. 10-2-1
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use 8 mm or 10 mm anchor bolts and nuts.
·
·
Air inlet
Air outlet
Drain outlet
600 mm
90 mm
125 mm108 mm
28 mm
86 mm
102 mm
320 mm
25 mm
Æ
FILE NO. SVM-12071
10-2-1. Optional installation parts
<Fixing bolt arrangement of outdoor unit>
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
Refrigerant piping
Liquid side : 6.35 mm
Gas side : 12.70 mm
Pipe insulating material
(polyethylene foam, 8 mm thick)
Putty, PVC tapes
10-2. Optional Parts, Accessories and Tools
If it is necessary to drain the defrost water, attach drain nipple
9
and cap w
ater proof
10
to the bottom
plate of the outdoor unit before installing it.
·