6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
2
3
4
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
MF-340-30-3
( — )
( — )
MSBPC20F04
DC340V, 30W
10k at 25°C
10k at 25°C
DC12V, 4phase, 16pole
No.
1
2
3
4
5
6
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Model name
CH-57-Z-T
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
L = 10mH, 16A
DC140V, 43W
10k (25°C)
62k (20°C), 3.3k (100°C)
10k (25°C)
10k (25°C)
7
8
9
10
DA150A1F-20F
CAM-MD12TCTH-5
Rating
20A, AC250V
3phases 4poles 1100W
DC12V
AC220–240V
Terminal block (5P)
Compressor
Coil for PMV
Coil for 4-way valve
JXO-5B
RAS-18N3AV2-E
RAS-22N3AV2-E
DA131S1B-31FZ
RAS-18N3AV2-E
RAS-22N3AV2-E
STF-01AJ646A1
STF-01AJ503K1
FILE NO. SVM-12056
19
Parts name Model name
Rating
Fan motor (for indoor)

Table of Contents