EasyManua.ls Logo

Toshiba RAS-18N3KV2-E - 10-3-5. Piping and drain hose installation (continued)

Toshiba RAS-18N3KV2-E
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-12056
CAUTION
Firmly insert the drain hose and drain cap; otherwise,
water may leak.
Slit
4 mm
<How to attach the drain cap>
1. Insert hexagon wrench (4 mm) in a center head.
No gap
Insert a hexagon
wrench (Ø4mm)
Do not apply lubricating oil
(refrigerant machine oil)
when inserting the drain cap.
If applied, deterioration and
drain leakage of the drain
plug may occur.
Fig. 10-3-15
2. Firmly insert drain cap.
Fig. 10-3-16
<How to attach the drain hose>
Always use the original screw that secured the
drain hose to the unit. If using a different screw
may cause water to leak.
Insert the drain hose firmly until the connector
contacts with the insulation, then secure it in place
using the original screw.
<In case of right or left piping>
After scribing slits on the front panel with a knife
or a making-off pin, cut them with a pair of nippers
or an equivalent tool.
Fig. 10-3-17
<Left-hand connection with piping>
·Bend the connecting pipe so that it is laid within
43 mm above the wall surface.
If the connecting pipe is laid exceeding 43 mm
above the wall surface, the indoor unit may
unstably be set on the wall.
When bending the connecting pipe, make sure to
use a spring bender so as not to crush the pipe.
Fig. 10-3-18
<In case of bottom right or bottom left piping>
After scribing slits of the front panel with a knife
or a making-off pin, cut them with a pair of
nippers or an equivalent tool.
Slit
Fig. 10-3-19
NOTE :
If the pipe is incorrectly, the indoor unit may unstably
be set on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipe to the auxiliary
pipes and wrap the facing tape around them.
To connect the pipe after installation of the unit (figure)
Bend the connecting pipe within a radius of 30 mm
43 mm
Use a screwdriver handle, etc.
(To the front flare)
Outward form of indoor unit
Gas side
520 mm
420 mm
R30 or less (Ø6.35), R50 or less (Ø12.70, Ø15.88)
Use polishing (polyethylene core or the like for bending pipe).
Liquid side
57