Toshiba RAS-18SKPX - Refrigeration Cycle Diagrams; Refrigeration Cycle (18 Series)

Toshiba RAS-18SKPX
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
FILE NO. SVM-08032
5-1. RAS-18SKPX / RAS-18S2AX, RAS-18SKPX-V / RAS-18S2AX-V
RAS-18SKP-E / RAS-18S2A-E
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.46 12.5 High 27/19 35/24
Cooling High temperature 0.51 17.5 High 32/23 43/26
Low temperature 0.32 6.5 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Cross flow fan
Compressor
Propeller fan
Outdoor unit
SHX33SC4-U
O.D.:12.7 mm O.D.:6.35 mm
Packed valve
(12.7)
Packed valve
(6.35)
T
P
Refrigerant
R22 1.23 kg
0.39 m
(Connecting pipe)
12.7
0.49 m
(Connecting pipe)
6.35
Mark ( ) means check points of Gas Leak
Capillary tube
2.0x1100 s
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Heat exchanger
Heat exchanger
Discharge Muffler
25x160L
5. REFRIGERATION CYCLE DIAGRAM