FILE NO. SVM-08032
56
9-7-2. How to shorten time of restart delay timer
1 Press [SET] button while pressing [CHECK] button
with a tip of a pencil.
2 Then press [
] button to transmit the signal to the
indoor unit.
Table 9-
7
-2.
Approximate resistance value of thermo sensor
Temperature 0°C10°C20°C25°C30°C
Resistance value 33.8 20.35 12.59 10.00 7.99
(k)
9-
7
-3.
How to set/cancel self cleaning function
The self cleaning function is set from a factory. To cancel this function, should keep press the RESET button on
Indoor unit for 20 seconds till can hear the long combination sound and repeat the same procedure when need
to set.
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHK
CLOCK
OFF
CLR
SLEEP
SET
FIX Hi-POWER ECO
COMFORT
SLEEP
MODE
TEMP
FAN
1