FILE NO. SVM-05016
5-3. RAS-24NKD-E4 / RAS-24UA-E4, RAS-24NKDX4 / RAS-24UAX4,
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.38 11.0 High 27/19 35/24
Cooling High temperature 0.50 12.0 High 32/23 43/26
Low temperature 0.30 1.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Evaporator
Indoor unit
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Cooling
O.D.:15.88 mm O.D.:6.35 mm
Cooling
Gas container connection (Reinstall etc.)
Packed valve
(6.35)
Packed valve
(15.88)
0.39 m
(Connecting pipe)
15.88
0.49 m
(Connecting pipe)
6.35
T
P
Refrigerant
R22 1.
70
kg
Mark ( ) means check points of Gas Leak
Capillary tube
2.4x1500 s
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Dryer
PH400X3CS-4KT1
Compressor
RAS-24NKDX4-T / RAS-24UAX3-T1