EasyManua.ls Logo

Toshiba RAS-18UKHP-ES2 - 10-4. Outdoor Unit (RAS-18 UA-ES2)

Toshiba RAS-18UKHP-ES2
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-03009
67
10-4 Outdoor Unit (RAS-18UA-ES2)
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the electrical parts cover.
(2 screws 4 x 10L)
3) Remove 2 cord clamps (4 screws 4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screws on the terminal block
and 1 ground screw on the electrical parts base.
4) Remove the front cabinet. (8 scerws 4 x 10L)
(Pull the front lower portion toward you, and pull out
it upward to remove it.)
5) Remove the back cabinet. (4 screws 4 x 10L)
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw 4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw 4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Unlatch the relay and pull it upward.
3) Disconnect the lead wires from the relay terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw 4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the terminal cover of compressor.
3) Remove the thermostat holder from the
compressor.
4) Disconnect the lead wires from the bimetal
thermostat.
1 Common
procedure
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
4 Relay
5 Spark killer
6 Bimetal thermostat
No. Part name Procedures Remarks
Remove
8 screws 4 x 10L
Bimetal thermostat
Spark killer
Running
capacitor for
compressor
Running
capacitor for
fan motor
Relay
4 screws 4 x 22L 4 screws 4 x 10L

Table of Contents