– 50 –
10-3. Indoor Unit
10-3-1. Installation Place
• A place which provides enough spaces around
the indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
inlet and outlet.
• A place which allows easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
opened.
• The indoor unit shall be installed so that the top of
the indoor unit is positioned at least 2 m in height.
• Also, avoid putting anything on the top of the
indoor unit.
CAUTION
• Direct sunlight on the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f sources.
(For details, see the owner’s manual.)
Remote controller
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
Fig. 10-3-1
10-3-2. Drilling a Hole and Mounting
Installation Plate
Drilling a hole
When install the refrigerant pipes from the rear.
Fig. 10-3-2
1. After determining the pipe hole position on the
installation plate (
ð
) drill the pipe hole (Ø65 mm)
at a slight downward slant to the outdoor side.
NOTE :
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
Mounting the installation plate
Fig. 10-3-3
Indoor unit
(Side view) (Top view)
Remote controllerRemote controller
Reception
range
Reception
range
Indoor unit
45˚
45˚
75˚
m from the right side edge is
e center of pipe hole
35 120 180 240
The center of the pipe hole is the above arrow.
Pipe hole
Dia .65mm
23mm
FILE NO. SVM-12002
T
o
u
n
i
t
o
u
t
l
i
n
e
2
4
0
m
m
T
o
u
nit
o
u
t
l
i
n
e
3
5m
m
T
o
u
n
i
t
o
u
t
l
i
n
e
2
4
0
m
m
Offset 23mm from the right side edge is
the center of pipe hole
T
o
u
nit
o
u
t
l
i
n
e
1
20
m
m
0
2
3
3
5
1
2
0
1
8
0
2
4
0
Offset 85mm from the left side edge is
the center of pipe hole
1
7
0
1
7
0
50
40
8
5
1
3
2
2
3
d
i
a
.
6
5
m
m
1
7
Anchor bolt holes
Hook
Hook
Hook
Pipe hole
Pipe hole (dia. 65mm)
Installation
plate
Weight
Indoor unit
Thread
2 m or more from floor
Mounting
Screw