87
No. Part name
Fan motor
Procedures
1) Follow to the procedure till item .
2) Loosen the set screw of the cross flow fan.
3) Remove two fixing screws of the motor cover
and them remove the motor cover.
4) Remove two more fixing screws of the
motor band and remove the motor band.
Remarks
5) Pull the fan motor outward.
Set screw
Two screws on
motor band
Two screws on
motor cover
FILE NO. SVM-12002