7
Toshiba 1115551210 (EN)
Drainage
1. Run the drain hose sloped downwards.
Do not rise the
drain hose.
Do not form the drain hose
into a wavy shape.
50 mm
or more
Do not put the drain
hose end into water.
Do not put the drain
hose end in the
drainage ditch.
Information
The lower part of indoor unit may fl oat,
due to the condition of piping and you
cannot fi x it to the installation plate. In
that case, use the % screws provided
to fi x the unit and the installation plate.
NOTE
The hole should be made at a slight downward slant on the outdoor side.
% Screw
% Screw
This air conditioner has the structure designed
to drain water collected from dew, which forms
on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and
other parts at a height above the drain guide.
Shield pipe
Drain hose
Extension drain hose
Inside the room
2. Put water in the drain pan and make sure that the water is drained out of
doors.
3. When connecting extension drain hose, insulate the connecting part of
extension drain hose with shield pipe.
CAUTION
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
1
2
Indoor Unit Fixing
Accessory Parts
For detaching the indoor unit from the
installation plate, pull the indoor unit
toward you while pushing its bottom
up at the specifi ed parts.
1. Pass the pipe through the hole in the wall and hook the indoor unit on the
installation plate at the upper hook.
2. Swing the indoor unit to right and left to confi rm that it is fi rmly hooked up
on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the lower part on
the installation plate. Pull the indoor unit toward you to confi rm that it is
rmly hooked up on the installation plate.
OUTDOOR UNIT
OUTDOOR UNIT
Hook here.
Hook
Press
(unhook)
Push Push
NOTE
If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipes to the auxiliary pipes and wrap the facing tape around them.
CAUTION
Bind the auxiliary pipes (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
Carefully arrange pipes so that any pipe does not stick out of the rear
plate of the indoor unit.
Carefully connect the auxiliary pipes and connecting pipes to one another
and cut off the insulating tape wound on the connecting pipe to avoid
double-taping at the joint; moreover, seal the joint with the vinyl tape, etc.
Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material)
When bending a pipe, carefully do it, not to crush it.
Auxiliary pipes
Indoor unit
Connecting cable
Installation plate
1 Installation plate
Wall
Drain
guide
Space for pipes
Part name Q’ty Shape Usage
Cable tie
2
For fi xing the Power cord
Protective bush
1
For protecting wire (pipe cover)
Guard material for passage part
1
For protecting passage part (pipe cover)
Drain nipple
1
For Heat pump model
Waterproof rubber cap
5
For Heat pump model
TSB 1115551210_EN.indb 7TSB 1115551210_EN.indb 7 6/18/14 9:03 AM6/18/14 9:03 AM