EasyManua.ls Logo

Toshiba RAS-24NKHD-E5 - Outdoor Unit (RAS-18 N2 AX-T)

Toshiba RAS-24NKHD-E5
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-06010
4-3. Outdoor Unit (RAS-18N2AX-T)
4-4. Indoor Unit (RAS-24N2AX-T)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH290X2C-4FT1 Winding resistance () C-R C-S
(at 20°C) 1.71 3.09
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) FG-240-42A Winding resistance () Red-Black White-Black
(at 20°C) 128 126
3
Running capacitor
451305L AC 450 V, 3.0µF
(for fan motor)
4
Running capacitor
RA44B356U0215S AC 440 V, 35µF
(for compressor)
5 Magnetic contactor CLK-26J 220 – 240 V, 50 Hz
11
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 240 V, 50 Hz
1 Compressor PH400X3CS-4KT1 Winding resistance ( ) C-R C-S
(at 20 °C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 240 V, 50 Hz
Winding resistance ( ) Red-Black White-Black
2 Fan motor (for outdoor)
(at 20 °C)
128 126
FG-240-42A
AC 440 V, 50µF
1.13
2.10
3
Running capacitor
451305L
AC 450 V, 3.0µF
(for fan motor)
RS44B506U0218S
4
5 Magnetic contactor
A35
220 240 V, 50 Hz
Running capacitor
(for compressor)

Table of Contents