– 22 –
FILE NO. SVM-03009
7. OPERATION DESCRIPTION
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcomputer, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [FIX] button is pressed, it stops
swinging.
7-1-2. Indoor fan control (DC Fan motor)
(1) The indoor fan is operated by the stepless speed
change DC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
+
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
Table 7-1-1
7-1.Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
a DC motor for an indoor fan. The DC motor drive
circuit is mounted in the indoor unit. And electrical
parts which operate the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
The air conditioner is mainly controlled by the indoor
unit controller. The controller operates the indoor fan
motor based upon commands transmitted by the
remote control and transfers the operation commands
to the outdoor unit controller.
The outdoor unit controller receives operation
commands from the indoor unit, and operates the
outdoor fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation
commands from the remote control and executes
them.
Temperature measurement at the air inlet of the
indoor heat exchanger by the indoor
temperature sensor
Temperature setting of the indoor heat
exchanger by the heat exchanger sensor
Louver motor control
Indoor fan motor operation control
LED display control
Transferring of operation commands to the
outdoor unit
Receiving of information of the operation status
and judging of the information or indication of
error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation
commands from the indoor controller and
executes them.
Compressor operation
control
Operation control of
outdoor fan motor
Turning off the compressor and outdoor fan
when the outdoor unit receives the shutdown
command
Defrost control in heating operation
(Temperature measurement by the outdoor heat
exchanger and control for the four-way valve
and the outdoor fan motor) *Heat pump Model
only
MODEL
RAS-24UKHP-ES-1 RAS-18UKHP-ES2
Motor speed Air flow level Motor speed Air flow level
(rpm) (m
3
/h) (rpm) (m
3
/h)
Cooling HIGH 1350 950 1150 750
and MED 1150 750 1050 650
Fan only LOW 1000 600 900 530
HIGH 1350 950 1200 800
Heating MED 1200 800 1100 700
LOW 1050 650 950 570
MODEL RAS-24UKP-ES-1 RAS-18UKP-ES2
Cooling HIGH 1350 950 1150 750
and MED 1150 750 1050 650
Fan only LOW 1000 600 900 530
LOW
+
=
MED
+
=
LOW+MED
2
MED+HIGH
2
Operations according
to the commands
from the indoor unit