EasyManua.ls Logo

Toshiba RAS-24UKHP-ES-1 - Troubleshooting for Wiring (Interconnect cable and Serial Signal Wire)

Toshiba RAS-24UKHP-ES-1
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-03009
56
<Inspection procedure>
-Cooling and heating model-
Are TD and TE sensors normal?
(TD=17.9kat 50°C)
(TE=10kat 25°C)
Is it possible to start
unit by remote control?
Is it possible to detect
DC 15 60V between
2 and 3 on terminal block?
Is crossover cable normal?
Is it possible to detect
AC 12V on secondary side
(CN06) of transfer?
YES
YES
YES
YES
YES
YES
YES
Turn on power supply.
Does OPERATION
lamp blink?
YES
NO
Refer to item Power
can not be turned on .
NO
NO
Refer to 9-9 Troubleshooting
for Remote Control .
Connect crossover
cable properly.
NO
Replace transfer.
NO
Replace outdoor
P.C. board.
Replace sensors.
NO
Replace outdoor
P.C. board.
NO
Replace MG switch.
NO
Check TA and TC sensors
or refer to 01 04 in Table 9-4-1.
Does MG switch operate?
Is it possible to detect
DC 5V at IC61 and 12V at IC51?
Is it possible to detect
AC 220 240V at CN11?
(Next Page)

Table of Contents

Related product manuals