FILE NO. SVM-03009
– 65 –
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the electrical parts cover.
(4 screws ∅4 x 10L)
3) Remove 2 cord clamps (4 screws ∅4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screwson on the terminal
block and 1 ground screw on the electrical parts
base.
4) Remove the top cabinet. (7 screws ∅4 x 10L)
5) Remove the front cabinet. (2 screws ∅4 x 10L)
6) Remove the side cabinet
(4 screws ∅4 x 10L & 2 screws ∅4 x 14L)
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 10L)
3) Disconnect the housing from the P.C. Board.
1) Perform the common procedure 1
2) Disconnect the lead wires from the P.C. Board.
3) Remove P.C.Board after unhooking 4 clams.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the terminal cover of compressor.
3) Remove the thermostat holder from the compressor.
4) Disconnect the lead wires from the bimetal
thermostat.
10-2. Outdoor Unit (RAS-24UAH-ES-1, RAS-24UA-ES-1)
1 Common
procedure
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
4 Magnetic
contactor
5 Transformer
(24UAH-ES-1 only)
6 P.C. Board
(24UAH-ES-1 only)
7 Spark killer
(24UA-ES-1 only)
8 Bimetal thermostat
(24UA-ES-1 only)
No. Part name Procedures Remarks
Front cabinet Side cabinet
Top cabinet
Electrical
parts cover
4 screws ∅4 x 22L
P.C. Board
Running capacitor
for compressor
Magnetic contactor
Running capacitor
for fan motor
Transformer
RAS-24UAH-ES-1
Bimetal thermostat
Spark killer
Running capacitor
for compressor
Running capacitor
for fan motor
Magnetic contactor
RAS-24UA-ES-1