EasyManua.ls Logo

Toshiba RAS-B13J2KVSG-E - Specifications of Electrical Parts

Toshiba RAS-B13J2KVSG-E
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. Type name Specifications
1 Compressor
RAS-07, 10
KSK75D43UEZA 3-Phases (6-Poles) ; 550W
RAS-16
KSN108D22UFZ
3-Phases (6-Poles) ; 890W
2 Fan Motor WDF-340-A43-1 DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil PQ-M10012-000313 DC 12V
4 4-Way valve coil
DXQ-939 AC 220-240V
5 Reactor RAS-16 CH-69-Z-T L = 19mH, 10A
6 Suction temp. sensor (TS sensor) (Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor (TD sensor) (Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor (TO sensor) (Inverter attached)
9 Heat Exchanger temp. sensor (TE sensor) (Inverter attached)
10kΩ at 25°C
10 Terminal block (5 poles) JXO-5B
AC 250V, 20A
Parts name
10kΩ at 25°C
RAS-07,10, 16
RAS-13
SQ-A2522G-000352
AC 220-240V
No. Typeype Specificat
1
Fan Motor (for indoor)
2 Room temp. sensor (TA-sensor) (-) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) (-) 10kΩ at 25°C
5
Louver motor 24BYJ48-ST
Output (Rated) 4 phase, DC12V
Parts name
DRM-340-30-2
DC280-340V, 42W
4
Heat exchanger temp. sensor (TCJ-sensor)
10kΩ at 25°C
(-)
RAS-13
KSK89D53UFZ 3-Phases (6-Poles) ; 715W
- 23 -

Table of Contents

Other manuals for Toshiba RAS-B13J2KVSG-E

Related product manuals