FILE NO. SVM-15006
6
Unit model Indoor
RAS-B16N3KV2-E1
Outdoor RAS-16N3AV2-E
Cooling capacity (kW) 4.5
Cooling capacity range (kW) 0.8-5.0
Heating capacity (kW) 5.5
Heating capacity range (kW) 0.9-6.9
Power supply
Electric Indoor Operation mode Cooling Heating
characteristic Running current (A)
0.21-0.19 0.24-0.22
Power consumption (W) 30 35
Power factor (%)
65 66
Outdoor Operation mode Cooling Heating
Running current (A) 6.33-5.80 6.86-6.28
Power consumption (W)
1365 1485
Power factor (%) 98 98
Starting current (A) 7.10
COP (Cooling / Heating)
Operating Indoor High (Cooling / Heating) (dB-A) 45/45
noise Medium (Cooling / Heating) (dB-A) 40/40
Low (Cooling / Heating) (dB-A) 30/31
Outdoor (Cooling / Heating) (dB-A)
49/50
Indoor unit Unit model
RAS-B16N3KV2-E1
Dimension Height (mm)
275
Width (mm) 790
Depth (mm) 225
Net weight (kg) 10
Fan motor output (W) 30
Air flow rate (Cooling / Heating)
(m
3
/
/
min)
11.5/12.3
Outdoor unit Unit model RAS-16N3AV2-E
Dimension Height (mm) 550
Width (mm) 780
Depth (mm) 290
Net weicht (kg) 38
Compressor Motor output (W) 1100
Type Twin rotary type with DC-inverter variable speed control
Model DA131S1B-31FZ
Fan motor output (W)
Air flow rate (Cooling / Heating)
(m
3
min)
36/32
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
6.35
Gas side (mm)
12.7
Outdoor unit Liquid side (mm)
6.35
Gas side (mm)
12.7
Maximum length (m) 20
Maximum charge-less length (m) 15
Maximum height difference (m) 10
Refrigerant Name of refrigerant R410A
Weight (kg) 1.10
Wiring Power supply
connection Interconnection
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21-32/0-28
Outdoor (Cooling / Heating)
(
o
C)
-10-46/-15-24
Accessory Indoor unit Installation plate 1
Wireless remote controller 1
batteries 2
Remote controller holder 1
TOSHIBA IAQ Filter (long type) 1
Mounting screw
6 ( 4 x 25L)
Pan head wood screw
2 ( 3.1 x 16L)
Plasma air purifier -
Installation manual 1
Owner's manual 1
Outdoor unit Drain nipple 1
Water proof rubber cap 2
* The specification may be subject to change without notice for purpose of improvement.
3 Wires: Includes earth (Outdoor)
4 Wires: Includes earth
3.23/3.62
1Ph/50Hz/220-240V, 1Ph/60Hz/220V
43
2-2. Specification