97
NOTE :
However, GND circuit error inside of the motor may be accepted in some cases when the above check is
performed.
When the fan motor does not become normal even if P.C. board is replaced, replace the outdoor fan motor.
If the resistance value between
1 (Red lead) 2 (White lead)
2 (White lead) 3 (Black lead)
3 (Black lead) 1 (Red lead)
of the connector
(CN300 : Motor winding)
is 17 to 25, it is normal.
Turn OFF the breaker.
Fan motor is normal.
Does the fan rotate without trouble
when rotating it with hands?
Disconnect two connectors (CN300) of the
outdoor fan motor from the outdoor P.C. board.
(Outdoor P.C. board error)
Fan motor error
YES
YES
NO
NO
CN300
FILE NO. SVM-15006
RAS-16N3AV2-E