SERVICE MANUAL
OUTDOOR UNIT
<DIGITAL INVERTER>
RAV-GM561ATP-E (TR)
RAV-GM801ATP-E (TR)
RAV-GM1101ATP-E (TR)
RAV-GM1401ATP-E (TR)
RAV-GM561ATJP-E
RAV-GM801ATJP-E
RAV-GM1101ATJP-E
RAV-GM1401ATJP-E
AIR-CONDITIONER
(SPLIT TYPE)
FILE NO. SVM-18043-1
R32
Revised on June, 2018

Table of Contents

Other manuals for Toshiba RAV-GM1101ATP-E

Questions and Answers:

Toshiba RAV-GM1101ATP-E Specifications

General IconGeneral
BrandToshiba
ModelRAV-GM1101ATP-E
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY CAUTION

Definition of Qualified Installer or Qualified Service Person

Defines qualifications and knowledge required for installation and service personnel.

Definition of Protective Gear

Details protective gear required for various work activities.

Warning Indications on the Air Conditioner Unit

Explains warning labels and symbols displayed on the unit.

Precaution for Safety

Outlines critical safety measures and potential hazards during operation and maintenance.

SPECIFICATIONS

Outdoor Unit Specifications

Details technical specifications for outdoor units across different models.

Operation Characteristic Curve

Illustrates cooling and heating performance curves based on compressor speed and temperature.

SYSTEMATIC REFRIGERATING CYCLE DIAGRAM

Indoor Unit Diagrams

Shows refrigerating cycle diagrams for single and twin type indoor units.

Outdoor Unit Diagrams

Presents refrigerating cycle diagrams and operating data for outdoor units.

WIRING DIAGRAM

Wiring Diagram for GM561/GM801 Models

Illustrates the electrical wiring connections for specific outdoor unit models.

Wiring Diagram for GM1101/GM1401 Models

Details the electrical wiring for larger capacity outdoor unit models.

SPECIFICATIONS OF ELECTRICAL PARTS

Electrical Parts for GM561/GM801

Lists electrical components and their specifications for specific outdoor unit models.

Electrical Parts for GM1101/GM1401

Specifies electrical components and their details for higher capacity outdoor units.

REFRIGERANT R32 HANDLING AND SAFETY

Safety During Installation/Servicing

Provides crucial safety precautions for handling R32 refrigerant during installation and service.

Refrigerant Piping Installation

Covers guidelines for selecting and installing piping materials and joints for R32 systems.

Instructions for Re-use Piping of R22 or R407C

Outlines conditions and procedures for reusing existing refrigerant piping.

General safety precautions for using R32 refrigerant

Discusses safe practices for refrigerant recovery, decommissioning, and labelling.

OUTDOOR CONTROL CIRCUIT

Outline of Main Controls

Explains the primary control functions of the outdoor unit, including PMV control and temperature release.

Outdoor Print Circuit Board

Identifies components and connections on the outdoor unit's main printed circuit board.

TROUBLESHOOTING

Summary of Troubleshooting

Provides an overview of common issues and preliminary checks for wired and wireless remote controllers.

Troubleshooting Procedures and Error Codes

Details diagnostic procedures, check codes, and causes of common operational errors.

Table Inspection of Outdoor Unit Main Parts

Lists key outdoor unit components and procedures for checking their resistance values.

SETUP AT LOCAL SITE AND OTHERS

Calling of Error History

Describes how to access and view past error logs from the remote controller.

Group Control Operation

Explains how to set up and manage multiple indoor units operating under a single remote controller.

Outdoor Unit Service Switch Operations

Details how to use service switches and LED displays on the outdoor unit for diagnostics and settings.

Address Setup Procedure

Guides through the process of setting up unit addresses for proper communication and control.

REPLACEMENT OF THE SERVICE P.C. BOARD

Assembly Steps for P.C. Board Replacement

Provides step-by-step instructions for replacing the service P.C. board.

HOW TO EXCHANGE COMPRESSOR

Exchanging Procedure of Compressor (Outline)

Outlines the general steps involved in replacing the compressor.

DETACHMENTS

Detachment and Attachment Procedures for GM561/GM801

Details the steps for disassembling and reassembling specific outdoor unit models.

Detachment and Attachment Procedures for GM1101/GM1401

Outlines the procedures for removing and installing parts on larger capacity outdoor units.

EXPLODED VIEWS AND PARTS LIST

Parts List for GM561 Models

Provides exploded views and part numbers for the GM561 series outdoor units.

Parts List for GM801 Models

Lists exploded views and part numbers for the GM801 series outdoor units.

Parts List for GM1101/GM1401 Models

Details exploded views and part numbers for the GM1101 and GM1401 series outdoor units.

WARNINGS ON REFRIGERANT LEAKAGE

Check of Concentration Limit

Explains concentration limits for refrigerants in installation rooms and safety measures.