EasyManua.ls Logo

Toshiba RAV-GM401ATJP-E - User Manual

Toshiba RAV-GM401ATJP-E
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SERVICE MANUAL
OUTDOOR UNIT
<DIGITAL INVERTER>
RAV-GM301ATP-E (TR)
RAV-GM401ATP-E (TR)
RAV-GM301ATJP-E
RAV-GM401ATJP-E
AIR-CONDITIONER
(SPLIT TYPE)
FILE NO. SVM-18042-1
SVM-13072.indb 1SVM-13072.indb 1 11/01/13 1:53 PM11/01/13 1:53 PM
R32
Revised on June, 2018

Table of Contents

Other manuals for Toshiba RAV-GM401ATJP-E

Questions and Answers

  • J
    Joseph BeanAug 12, 2025
    What to do if Toshiba Air Conditioner does not cool down or warm up?
    • E
      Erin MitchellAug 13, 2025
      If your Toshiba Air Conditioner isn't cooling down or warming up, there are several things you can check: * Make sure that the air intake or discharge of the outdoor unit isn't blocked. * Ensure no doors or windows are open. * Check if the air filter is clogged with dust. * Verify the air volume isn't set to 'Low'. * Confirm the operation mode isn't set to 'Fan'. * Be sure the set temperature is appropriate.
  • T
    Tyler KirkAug 16, 2025
    What to do if my Toshiba RAV-GM401ATJP-E Air Conditioner unit does not run?
    • D
      Duane Coleman DDSAug 17, 2025
      If your Toshiba Air Conditioner unit isn't running, check the following: ensure there hasn't been a blackout, verify the circuit breaker hasn't blown, and confirm that the protective device hasn't been activated.
  • A
    Annette WestAug 20, 2025
    How to clean a contaminated filter in Toshiba RAV-GM401ATJP-E?
    • J
      justin34Aug 20, 2025
      To address a contaminated filter in your Toshiba Air Conditioner, wash the filter with water. If the filter is damaged, replace it.
  • J
    joshua04Aug 23, 2025
    How to clean dust or dirt clogging in drain pan of Toshiba RAV-GM401ATJP-E?
    • G
      Gregory LynchAug 23, 2025
      To resolve dust or dirt clogging or drain contamination in the drain pan of your Toshiba Air Conditioner, clean the drain pan and check the downward slope to ensure smooth drainage.
  • M
    Mrs. Kaitlyn LozanoAug 27, 2025
    How to clean dust or dirt clogging in heat exchanger of Toshiba Air Conditioner?
    • A
      Amanda HallAug 27, 2025
      If the heat exchanger in your Toshiba Air Conditioner is clogged with dust or dirt, wash it.
  • A
    April SanchezAug 31, 2025
    How to clean contaminated ceiling panel or louvers of Toshiba RAV-GM401ATJP-E?
    • R
      robertperryAug 31, 2025
      If the ceiling panel or louvers of your Toshiba Air Conditioner are contaminated, wash them. Alternatively, you can apply a repair coating.
  • G
    Gregory PowersSep 4, 2025
    How to fix vibration or balance issue in fan of Toshiba RAV-GM401ATJP-E?
    • P
      petersondanielleSep 4, 2025
      If the fan in your Toshiba Air Conditioner has a vibration or balance issue, replace the fan if the vibration or balance is terrible. If the fan is simply contaminated, brush or wash it.
  • F
    fletcherbaileySep 7, 2025
    What to do if there is rust or peeling of insulator in exterior of Toshiba RAV-GM401ATJP-E?
    • S
      Shannon JohnsonSep 7, 2025
      If there is rust or peeling of the insulator on the exterior of your Toshiba Air Conditioner, apply a repair coating.

Toshiba RAV-GM401ATJP-E Specifications

General IconGeneral
TypeSplit System
Cooling Capacity4.0 kW
Heating Capacity4.5 kW
Energy Efficiency Class (Cooling)A++
Energy Efficiency Class (Heating)A+
RefrigerantR32
Indoor Unit Dimensions (WxHxD)798 x 293 x 230 mm
Outdoor Unit Dimensions (WxHxD)780 x 550 x 290 mm
Power Supply220-240V, 50Hz
Indoor Unit Weight9 kg
Coefficient of Performance (COP)4.0

Related product manuals