Installation Manual
– 44 –
44-EN
13
MAINTENANCE
¡ Daily maintenance
Cleaning of air ¿lter
1
Push the button to stop the operation,
then turn off the circuit breaker.
After the cooling or dry operation, the
ventilation fan keeps running for
self-cleaning. Push the button twice
to stop the operation.
Take out the air ¿lter
1
Open the air intake grille until it stops, and
slightly raise the hook on the lower centre
of the air ¿lter.
The air intake grille should not be opened
further; otherwise, the arms may come off and
the air intake grille may fall down.
Air ¿lter
Cleaning with water or vacuum cleaner
If dirt is heavy, clean the air ¿lter by tepid water
with neutral detergent or water.
After cleaning with water, dry the air ¿lter
suf¿ciently in a shade place.
Mount the air ¿lter
2
Turn on the circuit breaker, then push the
button on the remote controller to
start the operation.
1,2
CAUTION
•
Do not start the air conditioner while leaving
air fi lter removed.