R410A
FILE NO. SVM-12004
SERVICE MANUAL
AIR-CONDITIONER
SPLIT TYPE
INDOOR UNIT
High Wall Type
RAV-SM566KRT-E, RAV-SM806KRT-E
RAV-SM566KRT-TR, RAV-SM806KRT-TR

Table of Contents

Other manuals for Toshiba RAV-SM566KRT-E

Questions and Answers

  • M
    Melanie JonesSep 23, 2025
    What to do if other unusual conditions are found in Toshiba Air Conditioner?
    • J
      James WatkinsSep 23, 2025
      If you notice any other unusual conditions with your Toshiba Air Conditioner, immediately stop running the unit, turn off the circuit breaker, and contact the dealer where you purchased the product.
  • D
    daviskerryAug 25, 2025
    What to do if my Toshiba RAV-SM566KRT-E does not run?
    • L
      Lisa JohnsAug 25, 2025
      If your Toshiba Air Conditioner isn't running, check for a blackout, a blown circuit breaker, or activation of the protective device (look for blinking operation indicator on the wired remote controller). Also, ensure that the air intake or discharge of the outdoor unit isn't blocked.
  • W
    William WilliamsAug 25, 2025
    What to do if the switch does not work properly on Toshiba RAV-SM566KRT-E?
    • T
      Thomas RichAug 26, 2025
      If the switch on your Toshiba Air Conditioner isn't working correctly, immediately stop running the unit, turn off the circuit breaker, and contact the dealer where you purchased the product.
  • M
    Michelle StephensonAug 27, 2025
    What to do if open phase is detected in Toshiba RAV-SM566KRT-E Air Conditioner?
    • V
      Vanessa MooreAug 27, 2025
      If your Toshiba Air Conditioner detects an open phase, it might be due to an incorrectly connected power wire. You should check the open phase and voltages of the power supply.
  • M
    Mary DeanAug 27, 2025
    What to do if Toshiba RAV-SM566KRT-E detects indoor unit water overflow?
    • M
      Mr. Robert AdamsAug 27, 2025
      If your Toshiba Air Conditioner detects water overflow, it could be due to drainage issues or a float switch activation. Check the drain pipe for any clogging, inspect the drainage system, and examine the float switch circuit and the indoor P.C. board.
  • O
    Olivia CrosbySep 16, 2025
    What to do if my Toshiba RAV-SM566KRT-E Air Conditioner circuit breaker often blows out?
    • D
      Debbie LozanoSep 16, 2025
      If the circuit breaker for your Toshiba Air Conditioner frequently blows, immediately stop running the unit, turn off the circuit breaker, and contact the dealer where you purchased the product.
  • R
    reillywilliamSep 13, 2025
    How to troubleshoot indoor unit-outdoor unit serial communication error on Toshiba RAV-SM566KRT-E Air Conditioner?
    • R
      Richard HicksSep 13, 2025
      To resolve an indoor unit-outdoor unit serial communication error on your Toshiba Air Conditioner, check the system interconnection wires, the indoor P.C. board, and the outdoor P.C. board.
  • M
    Michelle ParkerSep 14, 2025
    Why does the fan keep running on my Toshiba RAV-SM566KRT-E?
    • T
      Todd BlackwellSep 15, 2025
      The fan on your Toshiba Air Conditioner may continue running after the unit is stopped to self-clean the heat exchanger during drying.
  • A
    aschmidtSep 5, 2025
    What does indoor unit room temp. sensor (TA) error mean on Toshiba Air Conditioner?
    • R
      Richard GreenSep 5, 2025
      If your Toshiba Air Conditioner displays an error related to the indoor unit room temp. sensor (TA), it means an open-circuit or short-circuit of the room temp. sensor (TA) was detected. Check the room temp. sensor (TA) and the indoor P.C. board.
  • A
    Aaron RodriguezSep 3, 2025
    What does indoor unit heat exchanger sensor (TCJ) error mean on Toshiba RAV-SM566KRT-E?
    • K
      Kayla MeyerSep 3, 2025
      If your Toshiba Air Conditioner displays an error related to the indoor unit heat exchanger sensor (TCJ), it means an open-circuit or short-circuit of the heat exchanger sensor (TCJ) was detected. Check the heat exchanger sensor (TCJ) and the indoor P.C. board.

Summary

SAFETY CAUTION

1. SPECIFICATIONS

4. WIRING DIAGRAM

5. SPECIFICATIONS OF ELECTRICAL PARTS

6. REFRIGERANT R410 A

6-1. Safety During Installation;Servicing

Safety precautions for installation and servicing of R410A refrigerant.

6-2. Refrigerant Piping Installation

Guidelines for installing refrigerant piping with R410A.

6-3. Tools

Required tools for working with R410A refrigerant systems.

6-4. Recharging of Refrigerant

Procedure for recharging refrigerant into the air conditioning system.

6-5. Brazing of Pipes

Materials and techniques for brazing refrigerant pipes.

7. INDOOR CONTROL CIRCUIT

7-2. Control Specifications (High Wall Type)

Detailed control specifications for the high wall type unit.

8. TROUBLESHOOTING

8-1. Summary of Troubleshooting

Overview and initial checks for troubleshooting wired remote controller issues.

8-2. Troubleshooting (High Wall Type)

Troubleshooting procedures and error code explanations for high wall type units.

9. REPLACEMENT OF SERVICE P.C. BOARD

10. SETUP AT LOCAL SITE AND OTHERS

10.8. Group control operation

11. ADDRESS SETTING

Toshiba RAV-SM566KRT-E Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Built-in displayNo
Hose length (max)30 m
Remotely operatedYes
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)5600 W
Cooling capacity in watts (min)1500 W
Heating capacity in watts (max)6300 W
Cooling capacity in watts (nominal)5000 W
Cooling energy efficiency (EER, W/W)3.01
Heating energy efficiency (COP, W/W)2.75
Operating temperature (cooling) (T-T)-15 - 46 °C
Operating temperature (heating) (T-T)-15 - 15 °C
Seasonal efficiency rating (cooling) (SEER)5.77
Heating capacity in watts (nominal) (Average heating season)5300 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage220-240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A+
Power consumption (cooling) (max)1660 W
Power consumption (heating) (max)2440 W
Annual energy consumption (cooling)304 kWh
Hourly energy consumption (cooling)- kWh
Annual energy consumption (heating) (Average heating season)1539 kWh
Indoor unit typeWall-mountable
Indoor unit depth228 mm
Indoor unit width1050 mm
Indoor unit height320 mm
Indoor unit weight12000 g
Indoor units quantity1
Cooling airflow (indoor unit)840 m³/h
Indoor unit noise level (high speed)57 dB
Outdoor units quantity0