fan, power conversion circuitry and connectors.
Input ratings are:
115 VAC, 1.8 Amps or 230 VAC, 1.2 Amps
The power supply unit is shown in figure 1-10 and the output ratings
are specified in table 1-6.
<fig id=MMS\5200\52001_14.TIF>Figure 1-10</fig> Power supply unit
<fig id=MMS\5200\52001_15.TIF>Page 1-15</fig>
Table 1-6 Power supply unit output rating
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³DC voltage ³Maximum ³Regulation ³
³ (V) ³Current (A) ³Tolerance (%) ³
ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ +5 ³ 6.8 ³ +/- 5 ³
³ +12 ³ 3 ³ +/- 5 ³
³ -5 ³ 0.25 ³ +/- 5 ³
³ -12 ³ 0.3 ³ +/- 10 ³
³ +24 ³ 2.8 ³ + - 20 ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
<fig id=MMS\5200\52001_16.TIF>Page 1-16</fig>
File No. : 960-011
~~
DOC:MAINTENANCE MANUAL
MODEL:T5200
MODEL:T5200C
CHAP:2 PROBLEM ISOLATION PROCEDURES
SECT:2.1, GENERAL
DOC_ID:2.1 T5200
LANG:ALL
TEXT:
<fig id=MMS\5200\52002_1.TIF>Page 2-1</fig>
2.1 GENERAL
The problem isolation procedures described in part 2 are used to
isolate defective FRUs (field replaceable units).
The FRUs covered are:
1. Power supply unit
2. System board
3. FDD
4. HDD
5. Keyboard
6. Plasma display
Detailed replacement procedures are described in part 4 and test and
diagnostics program operations are described in part 3.
The following items are necessary for implementing the problem
isolation procedures.