(2) Select a format type number. Type the number. If 3 is
selected, the dump lists for the hard disk are displayed
automatically.
0: Display a dump list for a floppy disk (2DD)
1: Display a dump list for a floppy disk (2D)
2: Display a dump list for a floppy disk (2HD)
3: Displays a dump list for a hard disk.
(3) If 0, 1, or 2 is selected, the following message will appear.
If 3 is selected, the dump list will appear.
Select FDD number (1:A/2:B) ?
(4) Select an FDD drive number; the following message will then
appear.
Insert source disk into drive A:
Press any key when ready.
(5) Remove the diagnostics disk from the FDD and insert a source
disk; press any key. The Track number ?? message will
then appear. Type the track number and press Enter.
(6) The Head number ? message will then appear. Type the
head number and press Enter.
(7) The Sector number ?? message will then appear. Type the
sector number and press Enter. The dump list for the
floppy disk will be displayed.
(8) After a dump list appears on the screen, the Press number key
(1:up,2:down,3:end) ? message will appear.
1. Displays the next sector dump.
2. Displays a previous sector dump.
3. Displays the following message.
Another dump (1:Yes/2:No) ?
(9) If you type 1 the display will return to the message shown
after (1) above. If you type 2 the display will return
to the DIAGNOSTICS MENU.
~~
DOC:MAINTENANCE MANUAL
MODEL:T5200
MODEL:T5200C
CHAP:3 TESTS AND DIAGNOSTICS
SECT:3.23, SYSTEM CONFIGURATION
DOC_ID:3.23 T5200
LANG:ALL
TEXT:
<fig id=MMS\5200\52003_43.TIF>Page 3-43</fig>
3.23 SYSTEM CONFIGURATION
3.23.1 Program description