TRWS indicator user’s manual
Turn on power, scale will show “err4”, then show current total weight on platform,
press TARE key, display show 0.00, then remove goods in hopper, display will show
it’s weight in “-“ mode, press PRINT/M+ key, scale will print out weighing ticket,
mode3/mode4 only different is print format.
6.8 Peak Hold
TWP can operate peak hold function, maximum reading will be hold and will update
automatically when add goods.
For this function, select parameter P4 CHk to ModE 4
In the normal weighing mode press and key together to turn on
Peak hold operations, display will be indicate HOLD.
If want to turn off peak function, press and key together again
-9-