TM
TM
INSTALLATION MANUAL AUTOMATIC FAUCET
Thermal mixing valve faucet
Important Safeguards
(For your safety, please follow the instructions below.)
In this Instruction Manual, the following symbols are shown for safe and proper use
of your automatic faucet and in order to alert you to the possibility of personal injury
and damage to your property.
The symbols and their meanings are as follows.
Warning
Ignoring these symbols may cause
personal injury and/or property damage.
*Some models may have different components from the ones illustrated below.
Do not place the
Automatic Faucet
in a high humidity
area such as shower room or sauna.
This may cause damage.
Do not use in
humid area
Warning
Do not strike or kick the Automatic Faucet.
This may cause damage or water leakage.
Never attempt to disassemble, reassemble,
repair
or modify the Automatic Faucet
, unless you are an
electrician, or qualified service person.
This may cause property damage or personal injury.
Do not
disassemble
Do not strike
Specification
OGU3009E 2006.4
EcoPower
type Battery type
Model
number
Standard
Gooseneck
Power supply
-
-
Alkaline type AA batteries
1.5V 2pcs.
Battery life
Item
2 yrs. Life based on 4,000
cycles per month
Detection range
from the sensor
5-1/8"~7-7/8" (130~200 mm)
sensor is self-adjusting
Water supply
pressure
minimum required water pressure:
13 PSI (90 kPa) ( Flowing)
maximum water pressure:125 PSI (862 kPa)
check local building codes for maximum water
pressure allowed
Water supply connection
1/2" NPSM
TEL5GSC TEL3DSC
TEL5GGC TEL3DGC
Helix
TEL5GCCN
-
Fordham
TEL5GTCN
-
Axiom
TEL5GKCN
-
Ambient temperature
32~104
o
F(0~40
o
C)
Humidity Max. 90% RH
Flow rate
1.06 gallon per minutes (4 L/min.)
Duration of
water discharge
Discharge quantity
Max. 0.25 gallon per cycle (0.95 L/cycle) for
10 seconds type
10 seconds ( TEL5 N -10)
60 seconds (TEL5 N -60)
TM