Explains the properties of R32 refrigerant, including flammability and environmental impact.
Detailed precautions for safe operation and user maintenance, emphasizing electrical safety.
Detailed safety requirements for electrical installation, including circuit breakers and grounding.
Warning to use an insulated object when pressing the auxiliary button.
Critical warnings for cleaning, emphasizing power disconnection and avoiding water.
Troubleshooting steps for when the indoor unit doesn't receive the remote signal.
Warnings for critical malfunctions like overheating cords or burning smells.
Specific requirements for proper electrical grounding of the unit.
Emphasizes that all wiring must be done by a professional.
Table specifying minimum room areas based on refrigerant charge.
Steps for filling the refrigerant and precautions.
Steps to power on the unit and check its operation modes.
Emphasizes that incorrect pipe expanding causes refrigerant leaks.
Warnings regarding maintenance, repair, and installation environment.
Safety precautions for operating and maintaining the unit.
Warning against using heat sources to dry filters.
Safety guidelines for unit installation by qualified technicians.
Guidance on selecting appropriate electrical safety devices.
Warning to use an insulated object when pressing the auxiliary button.
Table listing error codes and troubleshooting steps.
Safety instructions to follow during installation.
Strict prohibition of open flames in the maintenance area.
Emphasizes that incorrect pipe expanding causes refrigerant leaks.