Page #1 background image
Installer’s Manual
Split System (R-410A)
38 Series Mini-Split
Inverter System
9,000 Btu/h to 24,000 Btu/h
June 2020 MS-SVN054H-EN
Models:
HP Outdoor Units: HP Indoor Units:
4TXK3809B1 4MXW3809B1
4TXK3812A1 4MXW3812A1
4TXK3818A1 4MXW3818A1
4TXK3824A1 4MXW3824A1

Questions and Answers:

Trane 38 Series Specifications

General IconGeneral
BrandTrane
Model38 Series
CategoryAir Conditioner
LanguageEnglish

Summary

Warnings and Cautions

General Warning and Caution Definitions

Defines warning symbols and provides general safety alerts for potential hazards.

Environmental Concerns

Discusses the environmental impact of refrigerants and the company's stance.

Responsible Refrigerant Practices

Outlines manufacturer's commitment to responsible refrigerant handling and regulations.

Safety Precautions

General Safety Guidelines

Essential safety measures for installation and operation to prevent hazards.

Pre-Installation Checklist

A list of checks to perform before starting the installation process.

Items Shipped and Necessary Tools

Items Shipped with the System

Lists components included with the indoor and outdoor units.

Necessary Tools for Installation

Details the required tools for performing the installation procedure.

Typical Installation Setup and Part Identification

Names and Functions of Each Part

Identifies and describes the components of the indoor and outdoor units.

Clearance Requirements

Connection Pipe Requirements and Operating Ranges

Connection Pipe Requirements

Details specifications for refrigerant piping, including diameter, length, and oil.

Operating Ranges

Defines the acceptable temperature ranges for heating and cooling operation.

Refrigerant Piping Precautions

Hazard of Explosion and Deadly Gases

Warns about explosion risks and toxic gases from improper refrigerant handling.

System Component Damage

Caution against exposing refrigerant connections to atmosphere, causing moisture ingress.

Nitrogen Purging While Brazing

Emphasizes nitrogen purging during brazing to prevent unit damage and capacity loss.

Installation Location Guidelines

Indoor Unit Installation Location

Criteria for selecting a suitable and safe location for the indoor unit.

Outdoor Unit Installation Location

Criteria for selecting a suitable and safe location for the outdoor unit.

Installing the Indoor Unit

Mounting Location and Preparation

Guidance on selecting and preparing the wall mounting location for the indoor unit.

Piping Hole Drilling

Instructions on drilling the wall hole for refrigerant and drain pipes.

Refrigerant Piping at Indoor Unit

Steps for connecting refrigerant pipes to the indoor unit, including torque specs.

Condensate Pipe Installation

Guidance on connecting and routing the drain pipe for condensate removal.

Indoor Unit Wiring

Instructions for connecting the power and communication wires to the indoor unit.

Binding Pipes and Cables

Methods for bundling and securing refrigerant pipes, power cable, and drain hose.

Hanging the Indoor Unit

Steps for securely mounting the indoor unit onto its wall bracket.

Installing the Outdoor Unit

Location and Mounting

Guidelines for selecting the outdoor unit location and securing it properly.

Condensate Management

Procedures for managing condensate from the outdoor unit, including drain connection.

Installing and Insulating Refrigerant Piping

Flaring Process

Step-by-step guide for creating flares on refrigerant pipes using specialized tools.

Bending Pipes

Instructions on how to bend refrigerant pipes correctly without causing damage.

Refrigerant Piping at Outdoor Unit

Procedure for connecting refrigerant pipes to the outdoor unit's service valves.

Insulating Refrigerant Piping and Connections

Guidance on insulating pipes and connections to prevent condensation and heat loss.

Piping Requirements and Oil Traps

Outdoor Unit Lower than Indoor Unit

Piping requirements and oil trap considerations when the outdoor unit is lower.

Outdoor Unit Higher than Indoor Unit

Piping requirements and oil trap considerations when the outdoor unit is higher.

Vacuum and Refrigerant Leakage Detection

Electrical Installation

Wiring Precautions and Safety

Essential safety guidelines and warnings for all electrical wiring tasks.

Outdoor Unit Wiring Connections

Detailed steps for connecting wires at the outdoor unit terminal block.

Stranded Wire Connections

Procedure for properly preparing and connecting stranded wires to terminals.

Electrical Requirements and Power Supply

Specifications for power supply, wiring, and grounding as per codes.

Cable Specifications and Grounding

Details on cable types, lengths, and grounding requirements for safe operation.

Controller Installation

Reference to manuals for installing and configuring controllers.

Post Installation and Testing

Post Installation Checklist

A final check of all installation steps and components before operation.

Test Operation Procedures

Steps for performing initial startup and testing of the unit's functions.

Refrigerant System Diagrams

Wiring Diagrams

Color Key for Wiring

Explanation of wire color codes used in the wiring diagrams.

9K-12K Outdoor Unit Wiring Diagram

Schematic for the 9K-12K model, showing electrical connections for the outdoor unit.

18K Outdoor Unit Wiring Diagram

Schematic for the 18K model, showing electrical connections for the outdoor unit.

24K Outdoor Unit Wiring Diagram

Schematic for the 24K model, showing electrical connections for the outdoor unit.

Indoor Unit Dimensions

Outdoor Unit Dimensions

Common Error Codes and Troubleshooting

Common Error Codes

Lists error codes, their malfunction types, and recommended solutions.

Troubleshooting

Troubleshooting Guide

Lists common operating conditions and their possible causes and solutions.

Auxiliary Operation

Indoor Unit Maintenance

Filter Cleaning and Replacement

Steps for cleaning and maintaining the indoor unit's air filter.

General Maintenance Procedures

Outdoor Heat Exchanger Cleaning

Instructions for cleaning the outdoor unit's heat exchanger.

Drain Pipe Inspection

Regular checks to ensure the drain pipe is clear and functioning correctly.

Pre-Seasonal Use Checks

Items to verify before operating the unit after a period of shutdown.

Post-Seasonal Use Maintenance

Tasks to perform after the unit has been used for a season.

Parts Replacement and Service

Information on obtaining replacement parts and after-sales service.