SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
November 2020
RRTT--SSVVXX5500JJ--EENN
Installation, Operation, and Maintenance
Packaged Rooftop Air
Conditioners Foundation
Cooling Only and Electric Heat
15 to 25 Tons, 60 Hz
Model Numbers: EBC180-300

Table of Contents

Questions and Answers

  • K
    Kayla FieldsJul 26, 2025
    What to do if my Trane Air Conditioner is cooling improperly?
    • P
      Patricia MendozaJul 26, 2025
      If your Trane Air Conditioner isn't cooling correctly, it could be due to failed cooling and heating set points on the thermostat. Try power cycling the 'R' input. Another potential cause is an open CC1 or CC2 24 Vac control circuit. In this case, check the CC1 and CC2 coils and the Frostat™ status, as well as the LED indicator in LSD.
  • L
    Lisa WattsAug 9, 2025
    How to reset cooling and heating lockouts on a Trane Air Conditioner?
    • J
      Jessica GrayAug 9, 2025
      Cooling failures and heating lockouts are reset in an identical manner. You can reset the system from the space by turning the 'Mode' selection switch at the thermostat to the 'Off' position, and then turning it back to the desired mode after about 30 seconds. Alternatively, you can reset the system at the unit by cycling the unit power off and then on using the disconnect switch.

Summary

Introduction

Proper Field Wiring and Grounding Required!

Emphasizes the necessity of qualified personnel for safe and compliant electrical wiring and grounding.

Personal Protective Equipment (PPE) Required!

Details essential PPE for technicians to prevent injury from electrical, mechanical, and chemical hazards.

Weights

Rigging

Provides instructions and warnings for safely lifting and positioning the unit using appropriate equipment.

Installation

Main Unit Power

Details requirements for connecting the main power supply, including wiring, grounding, and disconnect switches.

Pre Start

Start Up

JADE Controls - Low Leak Economizer Sequence of Operation

Outlines the operational logic and tables for the JADE controller's low leak economizer functions.

Maintenance

Troubleshooting

Standard Troubleshooting

Covers common failures and diagnostic steps for cooling and heating issues.

Low Leak Economizer - (LLE) Troubleshooting

Explains how to identify, clear, and troubleshoot alarms and faults related to the LLE system.

Trane Foundation EBC210 Specifications

General IconGeneral
CategoryAir Conditioner
ModelEBC210
Voltage208/230V
Phase1
RefrigerantR-410A
Heating CapacityNot Available
HSPF RatingNot Available