Do you have a question about the Trane 4TTR3030N and is the answer not in the manual?
Brand | Trane |
---|---|
Model Number | 4TTR3030N |
Category | Heat Pump |
Cooling Capacity (BTU/h) | 30000 |
Heating Capacity (BTU/h) | 30000 |
Refrigerant Type | R-410A |
Voltage (V) | 208/230 |
Phase | 1 |
Frequency | 60 |
Unit Weight (lbs) | 220 |
Compressor Type | Scroll |
Warning regarding electrical shock hazard during installation, testing, and servicing.
Safety guidelines for R-410A refrigerant and POE oil, including pressure and hygroscopic properties.
Extreme caution advised when opening the liquid line service valve due to pressure.
Step-by-step instructions for preparing and brazing refrigerant lines to service valves.
Procedure for pressurizing lines with nitrogen and checking for leaks using soapy solution.
Steps for evacuating the system to a specific micron level using a vacuum pump.
Procedure for opening the liquid service valve with a warning about pressure release.
Steps for powering up the system, setting the thermostat, and stabilization time.
Method for adjusting charge using subcooling for outdoor temps above 55°F.
Recommended charge method for outdoor temperatures below 55°F is weighing.
Checklist for final unit inspection and operational verification.