EasyManua.ls Logo

Trane 4TTR6048N User Manual

Trane 4TTR6048N
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
18-AC98D1-7D-EN
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANTThis Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
Condensing Units
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with
the installation. Should further information be desired or should particular problems arise which are not covered sufficiently for the
purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.
Note: The manufacturer recommends installing only approved matched indoor and outdoor systems. Some of the benefits of
installing approved matched indoor and outdoor split systems are maximum efficiency, optimum performance and the best overall
system reliability.
4TTR6018 – 061
Table of Contents
Section 1. Safety ..................................................................................... 2
Section 2. Unit Location Considerations ............................................. 3
Section 3. Unit Preparation.................................................................... 4
Section 4. Setting the Unit ..................................................................... 5
Section 5. Refrigerant Line Considerations ......................................... 5
Section 6. Refrigerant Line Routing ..................................................... 6
Section 7. Refrigerant Line Brazing ...................................................... 7
Section 8. Refrigerant Line Leak Check ............................................... 9
Section 9. Evacuation ............................................................................ 9
Section 10. Service Valves .................................................................. 10
Section 11. Electrical - Low Voltage ................................................... 10
Section 12. Electrical - High Voltage .................................................. 13
Section 13. Start Up.............................................................................. 14
Section 14. System Charge Adjustment............................................. 15
Section 15. Checkout Procedures ...................................................... 20
Section 16. Refrigeration Circuits........................................................20
Section 17. Wiring Diagrams................................................................23
Section 18. Pressure Curves................................................................37
Installation and Operation Manual
Question and Answer IconNeed help?

Do you have a question about the Trane 4TTR6048N and is the answer not in the manual?

Trane 4TTR6048N Specifications

General IconGeneral
Model4TTR6048N
TypeHeat Pump
SEER Rating16
HSPF Rating9.0
RefrigerantR-410A
Voltage208/230V
Phase1
Sound Level (Outdoor Unit)74 dB
Cooling Capacity48000 BTU/h
Heating Capacity48000 BTU/h
Compressor TypeScroll

Summary

Section 1. Safety

Electrical Safety Warnings

Alerts on risks associated with live electrical components during installation and service.

Refrigerant Handling and Safety Precautions

Details R-410A refrigerant safety, pressures, oil, and valve handling.

Section 5. Refrigerant Line Considerations

Section 7. Refrigerant Line Brazing Procedures

Preparing and Brazing Refrigerant Lines

Step-by-step guide for deburring, cleaning, purging, and brazing lines.

Section 8. Refrigerant Line Leak Check

Performing Refrigerant Line Leak Detection

Details pressurizing lines with nitrogen and checking for leaks using soapy solution.

Section 9. System Evacuation

Evacuating Refrigerant Lines and Coil

Instructions for evacuating the system to a specific micron level using a vacuum pump.

Section 11. Low Voltage Electrical Connections

Section 12. High Voltage Electrical Requirements

High Voltage Power Supply and Grounding

Covers power supply requirements, compliance, and grounding procedures.

Section 13. System Start-Up Procedure

Step-by-Step System Start-Up Guide

Outlines the sequence of steps for safely starting the installed HVAC system.

Section 14. System Charge Adjustment

Temperature Measurements for Charging

Explains measurement methods and charging approaches like subcooling and superheat.

Subcooling Charging Method in Cooling

Detailed procedure for adjusting system charge using subcooling at higher ambient temperatures.

Weigh-In Method for System Charging

Describes the weigh-in method for charging when other methods are not feasible.

Section 15. Checkout Procedures

Final Unit Operational and Checkout Checklist

A comprehensive list of checks for ensuring proper installation and operation.

Section 17. Wiring Diagrams

Section 18. Pressure Curves

Cooling Pressure Curves for 4TTR60xxN1 Series

Illustrates liquid and suction pressures vs outdoor temperature for N1 models.

Related product manuals