Malntenance Space Dlmenslon
For ceiling installation
Ceiling
For half concealed installation
>3" (80 mm) >6" (150 mm)
Installing The Indoor Unit
Connection pipe requirement
Model
Diameter
Maximum length
Maximum height
(between indoor
and outdoor)
Liquid side
Gas side
4MXX6518G1000AA
6.35 mm 12.70 mm 20 m 10 m
4MXX6524G1000AA
9.52 mm 15.88 mm 20 m 10 m
4MXX6536G1000AA
4MXX6548G1000AA
9.52 mm 19.05 mm 30 m 20 m
4MXX6560G1000AA
9.52 mm 19.05 mm 50 m 30 m
Install the room air conditioner as follows
Remove the intake grill and side cover
(1) Open the intake grill
(2) Remove the Side cover(Right and left side)
(3) This air conditioner can be set up to intake fresh air . The information about how to install for fresh-air intake
refer to “Fresh air intake” .
7 6
>0.4" (10 mm)
> 3" (80 mm)
>5" (150 mm)
INDOOR UNIT
Ceiling
Ceiling panel
INDOOR UNIT
Ceiling panel
0.4" (10 mm)