Service Facts
© 2013 Trane
NOTICE: The manufacturer has a policy of continuous product and product data improvement, and it
reserves the right to change design and specifications without notice.
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
WARNING:
HAZARDOUS VOLTAGE-
DISCONNECT POWER and DISCHARGE
CAPACITORS BEFORE SERVICING
SINGLE PACKAGED
GAS HEATING / ELECTRIC COOLING
4YCY4036B1075/1096B
PRODUCT SPECIFICATIONS
4YCY4036B-SF-1H
1 Certified in accordance with the Unitary
Air-Conditioner Equipment certification
program, which is based on AHRI
Standard 210/240. Sound Power val-
ues are not adjusted for AHRI 270-95
tonal corrections.
2 All models are certified to UL 1995.
Ratings shown are for elevations up to
2000 ft. For higher elevations reduce
ratings at a rate of 4% per 1000 ft.
elevation.
3 Convertible to LPG.
4 This value is approximate. For more
precise value, see Unit Nameplate.
5 Based on U.S. Government Standard
Tests.
6 Filters must be installed in return air
stream. Square footages listed are
based on 300 f.p.m. face velocity. If
permanent filters are used size per
manufacturer's recommendation with
a clean resistance of 0.05" W.C.
7 Standard Air - Dry Coil - Outdoor.
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]
Performance Heating
Input BTUH - 1st Stage (Natural Gas)
Input BTUH - 2nd Stage (Natural Gas)
AFUE
Temp. Rise — Min/Max (°F)
Orifice Qty / Drill Size (Natural Gas)
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacity
Fuse Size — Max. (amps)
Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT
Charge (lbs.)
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
4YCY4036B1075B
208-230/1/60
38000
1210
3.166
12.0 / 14.2
69
56250
75000
79.5
30 / 60
2 / #33
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3320
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A
7.80
1/2
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4YCY4036B1096B
208-230/1/60
38000
1210
3.166
12.0 / 14.2
69
72000
96000
80.0
40 / 70
3 / #37
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3320
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A
7.80
1/2
H X W X L
47.86 / 44.5 / 52.03
493 / 397
Question and Answer IconNeed help?

Do you have a question about the Trane 4YCY4036B1075 and is the answer not in the manual?

Summary

Product Overview

Product Specifications

Presents detailed technical specifications for the HVAC unit, including performance and component data.

Safety Information

General Safety Warnings and Precautions

Covers hazardous voltage, gases, and general safety procedures for installation and service.

Wiring Diagrams and Safety

High Voltage and Low Voltage Wiring Diagram

Detailed schematic showing electrical connections for the unit's components and control system.

Sequence of Operation

Safety Sequences

Details safety devices like TCO, rollout, and pressure switches and their protective functions.

Cooling Refrigeration Cycle

Troubleshooting Chart

System Faults: Refrigerant Circuit

Lists common refrigerant circuit faults and their primary/secondary causes.

System Faults: Electrical

Lists common electrical faults and their primary/secondary causes.

IGN Diagnostic Indicators

Overview

This document provides service information for the Trane 4YCY4036B-SF-1H and 4YCY4036B1075/1096B single packaged gas heating/electric cooling units.

Function Description

These units are single packaged systems designed for both gas heating and electric cooling. They are controlled by a comfort control (thermostat) and operate automatically once the desired mode (HEAT or COOL) is set. The indoor fan can be set to continuous operation (ON) or automatic (AUTO), with AUTO recommended in humid climates to prevent discomfort or high relative humidity. Safety devices are integrated to protect against abnormal operating conditions, such as excessive supply air temperature, flame rollout, or inadequate combustion air pressure.

Important Technical Specifications

Models: 4YCY4036B1075B and 4YCY4036B1096B Rated Volts/PH/Hz: 208-230/1/60 for both models.

Cooling Performance:

  • BTUH: 38000 for both models.
  • Indoor Airflow (CFM): 1210 for both models.
  • Power Input (KW): 3.166 for both models.
  • EER/SEER (BTU/Watt-Hr.): 12.0/14.2 for both models.
  • Sound Power Rating [dB(A)]: 69 for both models.

Heating Performance:

  • Input BTUH - 1st Stage (Natural Gas): 56250 (1075B), 72000 (1096B).
  • Input BTUH - 2nd Stage (Natural Gas): 75000 (1075B), 96000 (1096B).
  • AFUE: 79.5 (1075B), 80.0 (1096B).
  • Temp. Rise - Min/Max (°F): 30/60 (1075B), 40/70 (1096B).
  • Orifice Qty / Drill Size (Natural Gas): 2/#33 (1075B), 3/#37 (1096B).

Power Connection:

  • Volts/PH/Hz: 208-230/1/60 for both models.
  • Min. Brch. Cir. Ampacity: 26.2 for both models.
  • Fuse Size - Max. (amps): 40 for both models.
  • Fuse Size - Recmd. (amps): 40 for both models.

Compressor:

  • Type: SCROLL for both models.
  • Volts/Ph/Hz: 208-230/1/60 for both models.
  • R.L. Amps - L.R. Amps: 16.7/79 for both models.

Outdoor Coil:

  • Type: SPINE-FIN for both models.
  • Rows/F.P.I.: 2/24 for both models.
  • Face Area (sq.ft.): 15.49 for both models.
  • Tube Size (in.): 3/8 for both models.

Indoor Coil:

  • Type: PLATE FIN for both models.
  • Rows/F.P.I.: 4/15 for both models.
  • Face Area (sq.ft.): 3.54 for both models.
  • Tube Size (in.): 3/8 for both models.
  • Refrigerant Control: EXPANSION VALVE for both models.
  • Drain Conn. Size (in.): 3/4 FEMALE NPT for both models.

Outdoor Fan:

  • Type: PROPELLER for both models.
  • Dia. (in.): 23.4 for both models.
  • Drive/No. Speeds: DIRECT/1 for both models.
  • CFM @ 0.0 in. w.g.: 3320 for both models.
  • Motor - HP/R.P.M.: 1/5/830 for both models.
  • Volts/Ph/Hz: 208-230/1/60 for both models.
  • F.L. Amps/L.R. Amps: 1.1/1.9 for both models.

Indoor Fan:

  • Type: CENTRIFUGAL for both models.
  • Dia x Width (in.): 10 X 10 for both models.
  • Drive/No. Speeds: DIRECT/VARIABLE for both models.
  • CFM @ 0.0 in. w.g.: SEE FAN PERFORMANCE TABLE for both models.
  • Motor - HP/R.P.M.: 1/2 / VARIABLE for both models.
  • Volts/Ph/Hz: 200-230/1/60 for both models.
  • F.L. Amps/L.R. Amps: 4.3/4.3 for both models.

Combustion Fan:

  • Type: CENTRIFUGAL for both models.
  • Drive/No. Speeds: DIRECT/2 for both models.
  • Motor - HP/R.P.M.: 1/45/2800/1500 for both models.
  • Volts/Ph/Hz: 208-230/1/60 for both models.
  • FLA: 0.34 for both models.

Filter / Furnished:

  • Type Recommended: THROWAWAY for both models.
  • Recmd. Face Area (sq. ft.): 4 for both models.

Refrigerant:

  • Charge (lbs.): R410A, 7.80 for both models.

Gas Pipe Size (in.): 1/2 for both models.

Dimensions:

  • Crated (in.) H X W X L: 47.86/44.5/52.03 for both models.

Weight:

  • Shipping (lbs.) / Net (lbs.): 488/392 (1075B), 493/397 (1096B).

The units are certified in accordance with the Unitary Air-Conditioner Equipment certification program, based on AHRI Standard 210/240. Sound Power values are not adjusted for AHRI 270-95 tonal corrections. All models are certified to UL 1995. Ratings are shown for elevations up to 2000 ft; for higher elevations, ratings should be reduced by 4% per 1000 ft. elevation. The units are convertible to LPG.

Usage Features

Cooling Cycle: When the comfort control is set to COOL and the fan to AUTO, the compressor contactor (CC) and indoor fan motor (IDM) are energized. The compressor (CPR) and outdoor fan motor (ODM) operate, provided safety controls are closed. The indoor fan motor (IDM) also operates. The thermostat cycles the compressor and fans to maintain the desired temperature. If the comfort control fan is set to ON, the indoor fan motor (IDM) runs continuously, regardless of compressor and condenser fan operation.

Heating Cycle (2-stage thermostat):

  • 1st Stage Call: The control module (IGN) initiates a self-check. After verifying open pressure switch (PS) contacts, closed limit switch (TCO) contacts, and closed flame rollout (FL) switch, the induced draft blower (CBM) energizes on high speed for ~5 seconds. Once CBM reaches speed, PS contacts close, and CBM switches to low speed for a 20-second prepurge. The gas valve (GV) and spark igniter (IP) energize. The flame detector (FD) confirms ignition within 7 seconds. The indoor fan motor (IDM) energizes at low speed after ~45 seconds and continues throughout the heating cycle.
  • 2nd Stage Call (after 1st stage): The control signals a call for second stage heat. CBM energizes on high speed, and the gas valve opens to second stage. After ~30 seconds, the indoor blower energizes on high speed.
  • 2nd Stage Satisfied (1st stage still called): CBM reduces to low speed, and the gas valve reduces to first stage. After ~30 seconds, the indoor blower motor reduces to low speed.
  • 1st Stage Satisfied: The gas valve (GV) closes. CBM de-energizes after ~5 seconds postpurge. IDM continues for the fan off period (field selectable 60 or 90 seconds) before de-energizing.
  • 1-stage Comfort Control: If W1/W2 are jumped, the unit operates as a 1-stage system with a 10-minute delay for 2nd stage heat from 1st stage ignition.

Safety Sequences:

  • Temperature Limit Switch (TCO): Located on the blower barrier, it protects against excessive supply air temperature. If it opens, the gas valve closes, and operation is prevented until the switch closes.
  • Rollout Switch (RO): Located in the gas compartment near the burner inlet, it's a manual reset device protecting against flame rollout. If it opens, the gas valve de-energizes, and the control (IGN) locks out the system. The RO must be reset manually.
  • Pressure Switch (PS): Located in the upper right side of the gas compartment, it ensures adequate combustion air pressure. If pressure against the induced draft blower outlet is excessive, the PS reacts, shutting off the gas valve until acceptable combustion pressure is available.
  • Ignition Failure: If the control (IGN) doesn't sense flame within the first trial for ignition, the gas valve de-energizes. The IGN initiates a 60-second interpurge, followed by a second ignition attempt. This sequence repeats for a third attempt. If all three attempts fail, the control locks out.
  • Loss of Flame: If flame loss occurs during a heating cycle, the IGN closes the gas valve and cycles through the ignition trial sequence.
  • Control Lockout Reset: If a control lockout occurs, the IGN retries a complete ignition sequence in 1 hour. It can be manually reset by removing power or by turning the thermostat from ON to OFF for ~3 seconds, then back ON.

Maintenance Features

Refrigerant Charging (Cooling above 55°F OD Ambient): The preferred method is to weigh in the factory charge per the unit nameplate. If weighing is not practical, the following method can be used for systems with indoor TXVs:

  1. Indoor Temperature: Maintain between 70°F and 80°F.
  2. Stabilization: Allow the system to operate for a minimum of 20 minutes after charge adjustments to stabilize.
  3. Measurements: Measure Liquid Line Temperature and Refrigerant Pressure at service valves in the compressor compartment.
  4. Adjustment: Use the R-410A Subcooling Charging Table to match liquid line temperature and pressure. Add refrigerant to raise pressure or remove to lower pressure. Wait 20 minutes after each adjustment.
  5. Verification: Once correctly charged, refer to System Pressure Curves (page 3) to verify typical performance.

Troubleshooting Chart: A detailed troubleshooting chart is provided, categorizing faults into "Refrigerant Circuit" and "Electrical." It lists common system faults and their primary (P) and secondary (S) causes, such as:

  • Refrigerant Circuit: Liquid pressure too high/low, suction pressure too high/low, liquid refrigerant floodback (TXV/Cap. Tube System), I.D. coil frosting, compressor runs inadequate or no cooling.
  • Electrical: Compressor & O.D. fan do not start, compressor will not start but O.D. fan runs, O.D. fan won't start, compressor hums but will not start, compressor cycles on IOL, I.D. blower won't start.

IGN Diagnostic Indicators Flash Codes: The IGN control module provides diagnostic flash codes via an LED:

  • Steady OFF: Check power or failed board.
  • Slow Flash Rate (3/4 sec on, 1/4 sec off): Normal, no call for heat.
  • Fast Flash Rate (1/4 sec on, 1/4 sec off): Not used.
  • Steady ON: Normal, no call for heat.
  • 2 Flashes: System lockout: Failed to detect or sustain flame.
  • 3 Flashes: Pressure switch problem detected.
  • 4 Flashes: High Limit switch protection device open.
  • 5 Flashes: Flame sensed and gas valve not energized or flame sensed and no "W" signal.
  • 6 Flashes: Flame Rollout Switch open.
  • 7 Flashes: Thermostat miswired; W1 & W2. The pause between groups of fast flashes is 3 seconds.

General Safety:

  • Hazardous Voltage: Disconnect power and discharge capacitors before servicing.
  • Refrigerant Handling: Contains R-410A under high pressure. Recover refrigerant before opening the system. Use only R-410A and approved POE compressor oil.
  • Grounding: Reconnect all grounding devices after service.
  • Gas Safety: Exposure to fuel substances or by-products of incomplete combustion can cause health hazards. Gas piping must be done by a Licensed Plumber or Gas Fitter.
  • Explosion Hazard: Propane gas is heavier than air and may collect in low areas. Install a gas detecting warning device if the furnace is in a basement or confined space.
  • Unit Operation: Do not operate the unit without evaporator fan or coil access panels in place.
  • Technician Safety: Electrical supply must be disconnected and the main gas valve turned off during installation and service. If operating checks require the unit to be running, technicians must recognize hazards and proceed safely.

Trane 4YCY4036B1075 Specifications

General IconGeneral
Model4YCY4036B1075
TypeCooling Box
RefrigerantR-410A
Voltage208/230 V
Phase1
Compressor TypeScroll
SEER Rating14.5
Cooling Capacity36000 BTU/H