Installers Guide
June 2020
88-A4AC3001-1D-EN
SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or
altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all pre-
cautions in the literature and on the tags, stickers, and labels that are attached to the equipment.
Models
A4AC3018A1000A
A4AC3023A1000A
A4AC3024A1000A
A4AC3029A1000A
A4AC3030A1000A
A4AC3036A1000A
A4AC3042A1000A
A4AC3043A1000A
A4AC3048B1000A
A4AC3060A1000A
Note: “Graphics in this document are for representation only.
Actual model may differ in appearance.”
Condensing Units
Question and Answer IconNeed help?

Do you have a question about the Trane A4AC3048B1000A and is the answer not in the manual?

Trane A4AC3048B1000A Specifications

General IconGeneral
ModelA4AC3048B1000A
TypeHeat Pump
Cooling Capacity48000 BTU/H
Tonnage4 ton
SEER RatingUp to 14.5
HSPF RatingUp to 8.2
RefrigerantR-410A
Voltage208/230V
Phase1
Compressor TypeScroll

Summary

Section 1. Safety

Section 5. Refrigerant Line Considerations

Section 7. Refrigerant Line Brazing

7.1 Braze The Refrigerant Lines

Details the initial steps for brazing refrigerant lines, including pipe preparation and cleaning.

Section 8. Refrigerant Line Leak Check

8.1 Check For Leaks

Explains how to pressurize the system with nitrogen and check for leaks using soapy solution.

Section 9. Evacuation

9.1 Evacuate the Refrigerant Lines and Indoor Coil

Details the process of evacuating the system to a specific micron level for optimal performance.

Section 11. Electrical – Low Voltage

11.2 Low Voltage Hook-up Diagrams

Illustrates wiring configurations for various thermostat and furnace types for correct installation.

Section 12. Electrical – High Voltage

12.1 High Voltage Power Supply

States requirements for matching power supply to nameplate and adhering to national codes.

12.3 High Voltage Ground

Mandates grounding the unit according to national, state, and local codes for safety.

Section 13. Start Up

13.1 System Start Up

Guides through the steps for powering up and starting the system after installation is complete.

Section 14. System Charge Adjustment

14.2 Subcooling Charging in Cooling (Above 55° F Outdoor Temp.)

Details the subcooling method for charging in cooling mode when outdoor temp is above 55°F.

Section 15. Checkout Procedures and Troubleshooting

15.1 Operational And Checkout Procedures

Lists essential checks to perform after installation for optimal system performance.