14 88-A4AC4001-1D-EN
With Furnace With Variable Speed Furnace
• Units with pigtails require wirenuts for connections. Cap all unused wires.
In AC systems for multiple stages of heat, jumper W1 and W2 together if comfort control has only one stage of heat.
* If equipped with second stage heat
** When using a BK enabled comfort control, cut BK jumper and bypass Y and YLo at the furnace. Connect BK from comfort control
to
BK of the furnace
Thermostat Furnace Furnace
Outdoor
Unit
R
G
B
W1
W2
B
Y
R
G
B/C
W1
W2
24 VAC HOT
FAN
24 VAC
Common
COOL
HEATING
YY1
YY
Y
LO
Thermostat
Outdoor
Unit
R
G
B
W1
W2
B
R
G
B/C
Y1
W1
W2
24 VAC HOT
FAN
24 VAC
Common
COOL
HEATING
O
BK
BK
**
**
**