EasyManua.ls Logo

Trane A801X060BM3SAC - Furnace Installation Guidelines; Safety Practices and Precautions

Trane A801X060BM3SAC
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A801X-SF-1C-EN
9
MODEL A801X080CM5SAC A801X100CM5SAC A801X120DM5SAC
TYPE
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
RATINGS
(a)
Input BTUH 80,000 100,000 120,000
Capacity BTUH (ICS)
(b) (c)
65,400 81,800 95,700
Temp. Rise (Min.-Max.)
30 - 60 30 - 60 30 - 60
AFUE (%)
(c)
80 80 80
Return Air Temp. (Min. - Max.)
55°F - 80°F 55°F - 80°F 55°F - 80°F
BLOWER DRIVE DIRECT DIRECT DIRECT
Diameter Width (In.)
11 X 11 11 X 11 11 X 11
No. Used 1 1 1
Speeds (No.)
(d)
9 9 9
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP 1 1 1
RPM 1075 1075 1075
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 10.9 10.9 10.9
COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal
Drive No. Speeds
Direct - 1 Direct - 1 Direct - 1
Motor HP RPM 3300 3300 3300
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 0.30 0.30 0.34
FILTER Furnished? No No No
Type recommended High Velocity High Velocity High Velocity
High Vel. (No.-Size-Thk.)
1 20x25 1 in. 1 20x25 1 in. 1 24x25 1 in.
VENT PIPE DIAMETER Min (in.)
(e)
4 Round 4 Round 4 Round
HEAT EXCHANGER Type
Aluminized Steel Aluminized Steel Aluminized Steel
Gauge (Fired)
20 20 20
ORIFICES Main
Nat. Gas Qty. Drill Size
4 - 45 5 - 45 6 - 45
GAS VALVE
Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage
PILOT SAFETY DEVICE
Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS QTY
4 5 6
POWER CONN. V/Ph/Hz
(f)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (Amps)
14.1 14.1 14.1
Max. Overcurrent Protection (Amps)
15 15 15
PIPE CONN. SIZE (in.)
1/2 1/2 1/2
(a)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
(b)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 latest edition.
(c)
Based on U.S. government standard tests.
(d)
9 Speed constant torque ECM blower motor.
(e)
Refer to the Installer's Guide.
(f)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
PPrroodduucctt SSppeecciiffiiccaattiioonnss

Other manuals for Trane A801X060BM3SAC