Do you have a question about the Trane AM4A0A36S31SA Series and is the answer not in the manual?
Model | AM4A0A36S31SA |
---|---|
Type | Air Handler |
Refrigerant | R-410A |
Voltage | 208/230 V |
Phase | 1 |
Width | 21 inches |
Cabinet Insulation | Foil-faced |
Cooling Capacity | 36000 BTU/H |
Airflow | 1, 200 CFM |
Maximum External Static Pressure | 0.8 inches WC |
Filter Type | 1 inch |
Instructions for qualified personnel regarding safe installation and service of equipment.
Recommended minimum clearance dimensions for service and maintenance access.
Procedures and safety warnings for safely lifting and rigging unit sections.
Guidelines and warnings for safe forklift use, avoiding equipment damage.
Step-by-step instructions for installing filters, including safety warnings.
Diagrams showing filter placement configurations for various unit sizes.
Details on fan and motor assembly isolation and shipping tie-down removal.
Requirements for seismic response criteria compliance and installation.
Specifications for concrete anchors and bolts for seismic isolation installations.
Proper installation, piping, and trapping for satisfactory coil operation and to prevent damage.
Guidelines for proper drain pan trapping, piping, and operation to prevent water damage.
Typical piping configuration for Type NS steam coils and horizontal tubes.
Typical water coil piping configurations and self-venting requirements.
Information on handling refrigerants and component placement in refrigerant lines.
Critical factors for properly sizing and routing liquid lines in split-system applications.
Safety warnings regarding electrical hazards and capacitor discharge before servicing.
Mandates for qualified personnel to perform field wiring and grounding to prevent hazards.
Procedure for calibrating the operator display touch screen for accurate input.
Checklist of essential tasks to complete before operating the assembled and installed air handler.
Procedures to check fan isolation, wheel rotation, bearing lubrication, and belt tension.
Inspection of coil piping, drain connections, and refrigerant charge for proper operation.
Inspection of motor lubrication, windings, and overall condition for safe operation.
Instructions and notices regarding proper fan belt tensioning to ensure bearing and drive life.
Procedure for calibrating the transmitter and calculating airflow using its output signal.
Safety warnings for maintenance and troubleshooting procedures, emphasizing electrical and mechanical hazards.
An abbreviated guide to periodic maintenance tasks with recommended frequencies.
Guidelines for maintaining UV lights, including bulb cleaning and safety precautions.