SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
September 2021
1188--BBCC110066DD11--11CC--EENN
TRANE Link or ComfortLink II
Variable Speed Heat Pumps and Air Conditioners
4TWV8X24A1000A
4TWV8X36A1000A
4TWV8X48A1000A
4TWV8X60A1000A
4TTV8X24A1000A
4TTV8X36A1000A
4TTV8X48A1000A
4TTV8X60A1000A
TM
The Diagnostics Mobile App is available by scanning a QR
code located inside this unit or by searching for the Link
Diagnostics App in your App Store
®
.
NNoottee:: “Graphics in this document are for representation only. Actual
model may differ in appearance.”
NNoottee:: This unit can be used in Comfortlink
II (“clii”) mode or Link
mode.
Installer’s Guide
Question and Answer IconNeed help?

Do you have a question about the Trane ComfortLink II 4TTV8X48A1000A and is the answer not in the manual?

Trane ComfortLink II 4TTV8X48A1000A Specifications

General IconGeneral
Model4TTV8X48A1000A
BrandTrane
SeriesComfortLink II
TypeAir Conditioner
SEER RatingUp to 18
Compressor TypeTwo-Stage
RefrigerantR-410A
Energy Efficiency Ratio (EER)13
HSPFNot Applicable
Stages2
Voltage208/230V
Phase1
Frequency60 Hz
Cooling Capacity48, 000 BTU/H
Warranty10 years

Summary

SAFETY SECTION

Hazardous Voltage

Warning about severe personal injury or death from electrical hazards.

Refrigerant Oil Warning

Precautions regarding R-410A refrigerant and PVE oil.

Hot Surface Caution

Warning about potential burns from hot surfaces.

Contains Refrigerant Caution

Safety notice regarding high-pressure refrigerant systems.

Grounding Required Caution

Importance of proper grounding for electrical safety.

Service Valves Warning

Cautionary advice for opening service valves to prevent charge release.

Brazing Requirements Warning

Emphasizes brazing over mechanical connections and leak testing.

High Leakage Current Warning

Risks associated with high leakage current and essential earth connection.

400 Volt Electrical Hazard

Warning about severe personal injury or death from 400V electrical components.

Refrigerant Line Considerations

Refrigerant Line Brazing

Refrigerant Line Leak Check

Electrical – Low Voltage Communicating

Low Voltage Hook-up Diagrams in Link mode

Wiring diagrams for connecting units in Link mode.

Low Voltage Hook-up Diagrams in clii mode

Specific wiring diagrams for the clii communication mode.

Electrical – High Voltage

High Voltage Power Supply

Information on matching the high voltage power supply to the equipment nameplate.

High Voltage Disconnect Switch

Requirements for installing a disconnect switch and connection safety.

System Charge Adjustment

Subcooling Charging Corrections

Worksheet and process for determining subcooling corrections.

Subcool Charging Correction Charts

Charging the Unit

Defrost Control (Heat Pump only)